16 | English
1 609 92A 0C4 | (19.9.13) Bosch Power Tools
inserted in the power tool, it is held in position by means of a
spring.
To remove the battery 5, press the unlocking button 6 and
pull out the battery toward the front. Do not exert any force.
Changing the Tool (see figure AC)
Before any work on the machine itself (e. g. mainte-
nance, tool change, etc.) as well as during transport
and storage, remove the battery from the power tool.
There is danger of injury when unintentionally actuating
the On/Off switch.
Regularly clean the power tool’s air vents. The motor’s
fan will draw the dust inside the housing and excessive ac-
cumulation of powdered metal may cause electrical haz-
ards.
GDR 14,4 V-LI/GDR 18 V-LI/GDX 14,4 V-LI/GDX 18 V-LI:
Inserting
Pull the locking sleeve 2 forward, push the insert tool to the
stop into the tool holder 1 and release the locking sleeve 2 to
lock the insert tool.
Use only screwdriver bits with ball catch 11 (DIN 3126-
E6.3). Other screwdriver bits 13 can be used with a universal
bit holder with ball catch 12.
Removing
Pull the locking sleeve 2 forward and remove the insert tool.
GDS14,4V-LI/GDS18V-LI/GDX14,4V-LI/GDX18V-LI:
When working with an application tool, pay attention
that the application tool is connected securely on the
tool holder. When the application tool is not securely con-
nected with the tool holder, it can come off during applica-
tion.
Slide the application tool 14 onto the square drive of the tool
holder 1.
However based on the system, if the application tool 14 ap-
pears wobbly after connecting securely on the tool holder 1;
this has no influence on the function/safety.
Operation
Method of Operation
The tool holder 1 with the tool is driven by an electric motor
via a gear and impact mechanism.
The working procedure is divided into two phases:
Screwing in and tightening (impact mechanism in action).
The impact mechanism is activated as soon as the screwed
connection runs tight and thus load is put on the motor. In this
instance, the impact mechanism converts the power of the
motor to steady rotary impacts. When loosening screws or
nuts, the process is reversed.
Starting Operation
Inserting the battery
Use only original Bosch lithium ion batteries with the
voltage listed on the nameplate of your power tool. Us-
ing other batteries can lead to injuries and pose a fire haz-
ard.
Set the rotational direction switch 7 to the centre position to
protect the power tool against accidental starting.
Insert the charged battery 5 from the front into the base of the
power tool until the battery is securely locked.
Reversing the rotational direction (see figure D)
The rotational direction switch 7 is used to reverse the rota-
tional direction of the machine. However, this is not possible
with the On/Off switch 8 actuated.
Right rotation: For driving in screws and tightening nuts,
press the rotational direction switch 7 through to the left stop.
Left Rotation: For loosening and unscrewing screws and
nuts, press the rotational direction switch 7 through to the
right stop.
Switching On and Off
To start the machine, press the On/Off switch 8 and keep it
pressed.
The power light 9 lights up when the On/O ff switch 8 is slightly
or completely pressed, and allows the work area to be illumi-
nated when lighting conditions are insufficient.
To switch off the machine, release the On/Off switch 8.
To save energy, only switch the power tool on when using it.
Adjusting the Speed
The speed of the switched on power tool can be variably ad-
justed, depending on how far the On/Off switch 8 is pressed.
Light pressure on the On/Off switch 8 results in a low rotation-
al speed. Further pressure on the switch results in an increase
in speed.
Working Advice
Apply the power tool to the screw/nut only when it is
switched off. Rotating tool inserts can slip off.
The torque depends on the impact duration. The maximum
achieved torque results from the sum of all individual torques
achieved through impact. The maximum torque is achieved
after an impact duration of 610 seconds. After this dura-
tion, the tightening torque is increased only minimally.
The impact duration is to be determined for each required
tightening torque. The actually achieved tightening torque is
always to be checked with a torque wrench.
Screw Applications with Hard, Spring-loaded or Soft Seat
When in a test, the achieved torques in an impact series are
measured and transferred into a diagram, resulting in the
curve of a torque characteristic. The height of the curve corre-
sponds with the maximum reachable torque, and the steep-
ness indicates the duration in which this is achieved.
OBJ_BUCH-832-005.book Page 16 Thursday, September 19, 2013 1:55 PM
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GDS 14.4 V-LI P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GDS 14.4 V-LI P in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info