Fold the drill onto the drill fixture and reinsert the eccentric
bolt 3. Tighten the eccentric bolt 3 using the star handle 4.
Slide the star handle 4 right or left onto the feed pinion 15 in
order to drill.
Check the tight seating of the drill in the drill fixture.
To remove the drill from the drill stand, complete the steps in
reverse order.
Spacer Plate for Drilling Diameters of 300350 mm
(see figure C)
The spacer plate 18 (accessory) has to be additionally insert-
ed in order to drill holes of 300 mm to maximum 350 mm
diameter.
To do so, attach the machine adapter 14 to the spacer plate
18 so that the feather keys 13 of the machine adapter engage
into the corresponding slots on the spacer plate.
Then attach the spacer plate 18 including machine adapter
14 to the drill so that the feather keys 20 of the spacer plate
engage into the corresponding recesses of the drill. Insert the
four screws 19 of the spacer plate and tighten them using a
hex key (size 6 mm).
Then mount the drill on the drill stand as described above.
Fastening the Drill Stand
Note: Fasten the drill stand free from play to prevent jamming
of the core bit and the tearing out of segments.
Depending on the type and nature of the structural material,
fasten the drill stand where the bore hole is intended using an
anchor, with vacuum or with the quick-clamping column.
Positioning the Drill Stand before Fastening
Mark the centre of the bore hole you want to drill on the surface.
Mark the outer dimensions of the core bit you want to drill with,
using the centre of the bore hole as the centre of the bit.
Fasten the drill stand (with drill inserted) using anchors, vac-
uum or quick-clamping column so that the mounted core bit is
aligned with the marked dimensions.
Fastening with Anchor (see figure D)
For fastening of the drill stand to brickwork or concrete with
anchor (accessory), drill a separate anchor hole.
The following dimensions apply for the anchor hole:
Insert a concrete hammer-drive anchor or a brickwork anchor
21. Screw the quick-clamping spindle 22 into the anchor.
Position the drill stand, attach a washer, and then screw to-
gether with the wing nut 23. After levelling (see “Levelling”),
tighten the wing nut using an open-end spanner, size 27 mm.
Fastening with Vacuum (Accessory)
To fasten the drill stand with vacuum, you require a conven-
tional vacuum pump and a Bosch vacuum set (accessory).
The vacuum pump must meet the following minimum require-
ments:
The surface must be smooth and flat in order to fasten with
vacuum. Use on plaster or brickwork is not permitted.
Once the vacuum connection has been established, apply the
levelling screws 7 lightly to the surface so that the drill stand
is in a rigid position and the sealing ring relaxes slightly. Oth-
erwise the drill stand will sit very softly on the sealing ring.
Read and observe the operating instructions of the vacuum
pump and Bosch vacuum set in order to connect them.
The safety and operating instructions for the vacuum
pump and vacuum set are to be strictly observed!
Fastening with a Quick-clamping Column (see figure E)
You can fasten the drill stand between the floor and ceiling us-
ing a Bosch quick-clamping column (accessory). The clamp-
ing range is 1.7 m to 3 m.
Place one end of the quick-clamping column on the bottom
plate of the drill stand. The contact surface on the ceiling for
the other end of the quick-clamping column must be suffi-
ciently stable and resistant to slipping.
For fastening the quick-clamping column, read and observe
its operating instructions.
Levelling (does not apply for fastening with vacuum)
Turn the levelling screws 7 in or out individually until the spirit
level 17 (when mounting vertically) is precisely aligned.
Now, firmly fasten the drill stand with anchor attachment or
with the quick-clamping column.
Operation
Disconnect the plug from the power source before
making any adjustments or changing accessories.
Starting drills accidentally is the cause of some accidents.
After each adjustment on the drill stand, firmly retight-
en all screws.
Drilling-angle Adjustment
Loosen the cap nut 6 using the star handle 4.
Set the drill stand to the required drilling angle using the drill-
ing-angle scale 2. Observe the arrow next to the cap nut 6 for
the exact setting.
Tighten the cap nut 6 hand-tight using the star handle 4.
The drill stand must not be inserted until the cap nut 6
of the angle adjustment has been retightened.
Water Extraction
You require a water collection ring and a wet/dry vacuum
cleaner (both accessories) to collect the water escaping from
the bore hole during wet drilling.
Clearance from anchor holecentre of the intended bore
hole
optimal 285 mm
possible 275375 mm
Diameter Depth
Brickwork 20 mm 85 mm
Concrete 16 mm 50 mm
Volume flow: 6 m
3
/h
Vacuum at least: 80 % (–800 mbar)
OBJ_BUCH-2255-001.book Page 12 Thursday, October 30, 2014 1:59 PM
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GCR 350 Professional at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GCR 350 Professional in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info