Viewing information | 55US/CA
DWU1: High return valve
status
On | Off Status of the valve DWU1, for return temperature
raising
Solar heating support
status
On | Off Shows whether solar energy is currently available for
the heating network.
collector field 2 Menu for the system part 2nd collector field
TA: Temperature of
collector field 2
189.4 °F (87.4 °C) Temperature measured by collector temperature
sensor (TA) in 2nd collector field.
PA: Collector field 2
pump status
Running | Off Switch status of solar pump (SP) for the 2nd
collector field.
Collector field 2 shut
down
Yes | No Shows whether there has been an emergency
shutdown of the solar pump (PA) due to the
collectors overheating (TA).
PA: Coll field 2 pump run
time
5370hr Number of hours of duty of the solar pump (SP) for
the 2nd collector field since commissioning.
Reload system Menu for the system part drinking water reload.
TB: Temp at top of tank B 137.6 °F (58.7 °C) Temperature measured at top tank temperature
sensor (TB) in the solar tank B.
PB: DHW reload pump
status
Running | Off Switch state of the drinking water reload pump
Tank B status Fully charged | Partially
charged
Load status tank B.
High/low priority Menu for the system part low/high priority tank
system.
TC: Temp at bottom of
tank C
140.6 °F (60.3 °C) Temperature measured at bottom tank temperature
sensor (TC) in the solar tank C.
Currently charging Tank C | Solar tank Shows which tank is currently being charged (the
solar tank or tank C).
PC: Solar pump status On | Off Status of the second solar pump (PC) in the high/
low priority system.
DWUC: Hi/lo priority
valve status
On | Off Status of the high/low valve (DWUC) in the high/low
priority system.
Tank C status Fully charged | Partially
charged
Charge status tank C.
Priority tank charging
test
Running | Off Status of the test mode for charging the priority tank
Next priority tank
charging test at
5:30pm (17:30) Time for the next test for charging the priority tank.
Ext. heat exchanger Menu for the system part external solar heat
exchanger.
TD: External heat
exchanger temp
211.6 °F (99.8 °C) Temperature measured on the temperature sensor
(TD), external heat exchanger
PD: Secondary circuit
pump status
Running | Off Switch state of the high/low priority valve between
the external heat exchanger and the tank.
Menu structure INFO Display (example) Description
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch FW 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch FW 200 in the language / languages: English as an attachment in your email.

The manual is 6,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch FW 200

Bosch FW 200 Quick start guide - German - 2 pages

Bosch FW 200 Usermanual and installation guide - German - 84 pages

Bosch FW 200 Quick start guide - Dutch - 2 pages

Bosch FW 200 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info