42 | MAIN MENU settings US/CA
6.3 DHW program
Main menu: Domestic hot water
DHW and DHW recirculation pump
You can use this menu option either to ...
... Activate your individual DHW program
(Separate programs). Recommended for
systems with remote control FB100.
- or -
... connect the DHW program with your
heating program (As heating program). That
is useful if you frequently switch between
different heating programs. The DHW program
is then automatically adapted to suit.
Recommended for systems without remote
control FB100.
As heating program (Automatic mode
together with heating program):
With combi boiler:
Hot water On as long as the heating system
is in Comfort operating mode and for 1
hour afterwards (overrun time).
Otherwise hot water Off.
With hot water tank:
1 hour before the first heating circuit
switches to Comfort mode, the tank
starts heating up to the set hot water
temperature (Tank temp in Comfort
Mode
1)
). This setting remains active as
long as the heating system is in mode
Comfort .
If one of the two heating circuits is in mode
Economy (and the other is in mode
Economy or Frost ), the tank is kept
at the temperature set for Tank temp in
Eco Mode
1)
.
If both heating circuits are in Frost
mode then frost protection is also active
for the tank (60 °F (15 °C) fixed value).
With DHW recirculation pump for
domestic hot water tank:
Circulation pump On and circulation pump
starts according to setting
(Æ section 6.3.5 on page 47) if one of the
heating circuits is running in Comfort
mode.
Otherwise circulation pump Off.
Separate programs (independent timer
programs):
Automatic switching between hot water
On
2)
/ Off
2)
or different hot water
temperatures
3)
and circulation pump On /
Off according to the set programs.
Circulation pump cycles as per setting
(Æ Section 6.3.5 on page 47).
For menu structure and adjustment ranges
Æ page 35.
Set the hot water temperature
control on the boiler to the
maximum required domestic hot
water temperature.
If a DHW tank is connected to the
IPM after the low-loss header, set
the supply temperature controller
on the boiler to the right stop.
1) Setting hot water temperature
Æ Section 6.3.5 on page 47
2) Domestic hot water provided by combi
boiler
3) Domestic hot water provided by hot
water tank
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch FW 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch FW 200 in the language / languages: English as an attachment in your email.

The manual is 6,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch FW 200

Bosch FW 200 Quick start guide - German - 2 pages

Bosch FW 200 Usermanual and installation guide - German - 84 pages

Bosch FW 200 Quick start guide - Dutch - 2 pages

Bosch FW 200 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info