458024
64
Zoom out
Zoom in
Previous page
1/76
Next page
6 720 645 349 (2010/09)
64 | Troubleshooting
9.2 Troubleshooting without display
Problem Cause Remedy
Required room temperature
not achieved.
Thermostatic valve(s) set too low. Set thermostatic valve(s) higher.
Heating curve set too low. Set "Heating levels" for "Comfort" higher
or arrange for your contractor to correct
the heating curve.
Flow temperature controller on heating
appliance set too low.
Set flow temperature controller higher.
Reduce influence of solar optimisation if
necessary.
Air lock in heating system. Bleed radiators and vent heating system.
Heating lasts too long. "Heating up speed" set too low. Set "Heating up speed", for example, to
"Fast".
Required room temperature
greatly exceeded.
Radiators become too hot. Set thermostatic valve(s) lower.
Set "Heating levels" for "Comfort" lower
or arrange for your contractor to correct
the heating curve.
Installation location of FW 100
unfavourable, e.g. external wall, close to
window, in a draught, ...
Select a better installation location for
FW 100 and ask your heating contractor
to reposition it.
Excessive room temperature
fluctuations.
Temporary influence of external heat on
the room, e.g. through solar radiation,
lighting, TV, fireplace etc.
Arrange for your contractor to increase
"Room influence".
Select a better installation location for
FW 100 and ask your heating contractor
to reposition it.
Temperature rises instead of
falling.
Time incorrectly set. Check time setting.
Room temperature too high
during "Economy" and/or
"Frost" mode.
Building retains a lot of heat. Set an earlier switching time for
"Economy" and/or "Frost".
Incorrect or nocontrol. BUS connection of BUS subscribers
faulty.
Ask your heating contractor to check the
BUS connection against the wiring
diagram and correct it if required.
Controller can only be set to
automatic mode.
Operating mode selector faulty. Have FW 100 replaced by your contractor.
DHW cylinder does not heat
up.
DHW temperature controller on heating
appliance set too low.
Set DHW temperature controller higher.
Reduce influence of solar optimisation if
necessary.
Flow temperature controller on heating
appliance set too low.
Turn flow temperature controller on
heating appliance fully clockwise.
64


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch FW 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch FW 100 in the language / languages: English as an attachment in your email.

The manual is 4,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch FW 100

Bosch FW 100 User Manual - English - 40 pages

Bosch FW 100 Usermanual and installation guide - German - 76 pages

Bosch FW 100 Quick start guide - German - 2 pages

Bosch FW 100 Quick start guide - Dutch - 2 pages

Bosch FW 100 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info