458017
52
Zoom out
Zoom in
Previous page
1/88
Next page
6 720 645 347 (2010/09)
52 | Viewing information
Heating system
Identification CH circuit 1 Currently assigned heating circuit.
Operating mode Auto – Comfort | Auto –
Economy | Auto – Frost |
Comfort | Economy |
Frost | Holiday – Auto |
Holiday – Comfort |
Holiday – Economy |
Holiday – Frost
Current operating mode or special mode for the
assigned heating circuit.
Required room temp 25.0 °C Required room temperature for the assigned heating
circuit.
Current room temperature 22.0 °C Room temperature measured at the controller.
Required heating output 45 % Output requested by the controller (only in the case
of analogue connection of the FR 100 via 1-2-4
interface).
Required CH flow
temperature
75.0 °C Flow temperature for the assigned heating circuit
calculated and requested by the controller.
Current CH flow temperature 47.0 °C Actual flow temperature captured in the assigned
heating circuit.
Heating pump On | Off Switching state of the heating circuit pump in the
assigned heating circuit.
Current mixer setting 85 % open Current opening state of mixer in the assigned
heating circuit.
Domestic hot water
Operating mode Immediate DHW | Auto
On | Auto Off | Holiday –
Auto | Holiday On | Holiday
Off
Current operating mode or special mode for DHW
with combi boiler.
Immediate DHW | Thermal
disinfection | Auto |
Holiday – Auto |
Holiday 15 °C
Current operating mode or special mode for DHW
cylinder.
Required DHW temperature 60.0 °C DHW temperature requested by controller.
Current DHW temperature 40.0 °C Current measured DHW temperature.
Domestic hot water status Running | Off Current status of DHW heating.
Last thermal disinfection
1)
Completed| Cancelled|
Running
Status of last thermal disinfection.
Customer service
2)
– –
Phone number (Telephone number) Telephone number of heating contractor (system
installer).
Name (Name) Name of heating contractor (system installer).
Menu structure INFO Display (example) Description
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch FR 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch FR 100 in the language / languages: English as an attachment in your email.

The manual is 4,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch FR 100

Bosch FR 100 User Manual - German - 40 pages

Bosch FR 100 User Manual - Dutch - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info