746999
19
Zoom out
Zoom in
Previous page
1/20
Next page
en Installation
18
Fitting with a flue duct Fitting without a flue duct
Installation
Screw in the mounting supports for the extractor hood
until they are hand-tight, use a spirit level to level the
appliance and then screw the mounting supports in
fully.
[
PP
PP
PP
PP
PP
PP
PP
PP
$
PP
PP
%
[
PP
PP
[
[
PP
PP
PP
PP
PP
PP
PP
$
%
PP
Installation en
19
Wall-mounting the appliance and levelling it
1. First remove the protective film from the back of the
appliance and, following installation, remove the rest
of the film.
2. When mounting the appliance, ensure that it
engages properly with the mounting supports.
3. If required, the appliance can be moved to the right
or to the left.
4. Firmly tighten the screws for the mounting supports.
Hold the bracket firmly when doing so.
¨
5. If no duct is to be fitted, screw in the two locking
screws without the bracket. ©
Connecting the pipes
If the extractor hood is to be operated in exhaust-air
mode, the pipes must be connected. If the extractor
hood is to be operated in air-recirculation mode, an
optional accessory must be fitted. To do this, refer to
the installation instructions provided.
Note: If an aluminium pipe is being used, smooth the
connection area beforehand.
Exhaust air pipe, dia. 150 mm (recommended size)
Fit the exhaust air pipe directly to the air-pipe connector
and seal the joint.
Exhaust air pipe, dia. 120 mm
1. Fit the reducing connector directly to the air-pipe
connector.
2. Attach the exhaust air pipe to the reducing
connector.
3. Use suitable means to seal both joints.
Attaching the flue duct
If the extractor hood is to be operated in exhaust-air
mode, a flue duct must be fitted.
The flue duct does not need to be fitted for air-
recirculation mode.
:Warning
Risk of injury!
From sharp edges during installation. Always wear
protective gloves while installing the appliance.
:Warning
Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do
not kink or pinch the connecting cable during
installation.
1. Separate the flue duct sections by removing the
adhesive tape.
2. Remove the pieces of protective film from both flue
duct sections.
3. Push one flue duct section into the other.
Notes
To prevent scratches, lay paper over the edges of
the outer flue duct section to protect the surface.
The slots of the inner flue duct section point
downwards.
4. Place flue ducts sections on the appliance.
5. Slide the inner flue duct section upwards, attach it to
the left and right sides of the retaining bracket, and
then slide it down to engage it.
¨
6. Screw the flue duct section to the sides of the
retaining bracket using two screws.
©
7. Clip the lower flue duct section in at the retaining
bracket. The connection cable must not be
damaged. ª
Note: If an air-recirculation optional accessory has been
fitted and the extractor hood is to be operated without a
flue duct, the cable must be wound onto the connector.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch DWK98JQ69 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch DWK98JQ69 in the language / languages: English as an attachment in your email.

The manual is 2,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch DWK98JQ69

Bosch DWK98JQ69 User Manual - German - 20 pages

Bosch DWK98JQ69 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info