108426
21
Zoom out
Zoom in
Previous page
1/80
Next page
21
Prior to installation
Flat ducts must have an internal cross-
section that equates to that of round
pipes.
There should be no sharp bends.
l 100 mm approx. 178 cm
2
l 125 mm approx. 113 cm
2
If pipes have different diameters:
Insert sealing strip.
For exhaust-air mode, ensure that
there is an adequate supply of fresh air.
Connecting a l 125 mm exhaust-air
pipe:
Mount the pipe directly onto the air
outlet on the hood.
Connecting a l 100 mm exhaust-air
pipe:
Attach the reducing connector
(enclosed or available from specialist
retailer) to the air pipe and then attach
to the exhaust-air duct.
For operating in exhaust-air mode, a
one-way flap should be mounted inside the
extractor hood unless there is already one
fitted in the outlet duct or wall ventilation
box.
If no one-way flap was enclosed with the
hood, it can be obtained from a specialist
retailer.
Installing the one-way flap:
Snap the one-way flap into the air pipe.
The two lightly sprung flaps must be
able to move upwards.
For optimum extractor hood efficiency:
Short, smooth air exhaust pipe.
As few bends in the pipe as possible.
Diameter of pipe to be as large as
possible and no tight bends in pipe.
If long, rough exhaust-air pipes,
many pipe bends or smaller pipe
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.
Round pipes:
We recommend
Internal diameter: 125 mm (at least
100 mm).
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch DKE 945 B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch DKE 945 B in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 4,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch DKE 945 B

Bosch DKE 945 B User Manual - English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish - 124 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info