13
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
¡The connection data can be found on the rating
plate. →Page10
¡The connecting cable is approx.1.30m long.
¡This appliance complies with the EC interference
suppression regulations.
¡The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.
¡Do not connect the appliance to the power supply
during installation.
¡Ensure that the protection against contact is guaran-
teed during installation.
12.7 Information on the installation situation
¡Install this appliance in a kitchen cupboard.
¡To install additional special accessory parts, ob-
serve the enclosed installation instructions.
¡The appliance must be installed with no more than
one side directly next to a high-sided unit or a wall.
The distance between the appliance and wall or
high-sided unit must be at least 50mm.
12.8 Instructions for the exhaust air pipe
The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.
¡Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.
¡Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.
¡Use an exhaust pipe that is made of non-combust-
ible material.
¡To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.
Round pipes
Use round pipes with an inner diameter of 150mm (re-
commended) or at least 120mm.
Flat ducts
Use flat ducts with an inner cross-section that corres-
ponds to the diameter of the round pipes:
¡Diameter of 150mm corresponds to ap-
prox.177cm².
¡Diameter of 120mm corresponds to ap-
prox.113cm².
¡Use sealing strips for different pipe diameters.
¡Do not use any flat ducts with sharp bends.
12.9 Instructions for the air extraction mode
For air extraction mode, a one-way flap should be in-
stalled.
Notes
¡If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.
¡If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.
12.10 Information about circulating-air
mode
The appliance must only be operated when it is se-
curely installed and the pipework is connected.
12.11 Installation
Checking the unit
1. Check whether the fitted unit is level and has suffi-
cient load-bearing capacity.
The max. weight of the appliance is 10kg.
2. Ensure that the fitted unit is heat-resistant up to
90°C.
3. Ensure that the fitted unit is still stable after the cut-
outs have been made.
Preparing the units
Requirement:The unit is suitable for the installation.
→"Checking the unit", Page13
1. Make the cut-out for the appliance.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch DHL785CGB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch DHL785CGB in the language / languages: English as an attachment in your email.

The manual is 2.95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info