109763
25
Zoom out
Zoom in
Previous page
1/96
Next page
25
Prior to installation
Connecting the l 120 mm
exhaust-air pipe:
Cut out the protective grid in the air
outlet.
Circulating-air mode
With activated carbon filter if exhaust-air
mode is not possible.
The complete
installation set can
be obtained from
specialist outlets.
The corresponding
accessory numbers
can be found at the
end of these opera-
ting instructions.
O
100
120
Exhaust flows straight out at the
back:
– inside the wall cupboard –.
Cut a hole in the rear panel of the wall
cupboard, including a groove for the
mains cable.
Connecting the l 100 mm
exhaust-air pipe:
Cut out the protective grid in the air
outlet.
Attach the reducing connector (enclosed
or can be obtained from specialist
retailers) to the air outlet.
Electrical connection
This is what you have to do:
1.Connect the green and yellow (Earth)
wire to the terminal in the plug marked
‘E’ or with the symbol ( ), or
coloured green or green and yellow.
2.Connect the blue (Neutral) wire to the
terminal in the plug marked ‘N’ or
coloured black.
3.Connect the brown (Live) wire to the
terminal marked ‘L’, or coloured red.
The extractor hood may only be
connected to an earthed socket that has
been installed according to the relevant
regulations. If possible, site the earthed
socket directly above the wall cupboard or
in its immediate vicinity.
Electrical data:
Are to be found on the name plate inside
the appliance after removal of the filter
frame.
Before undertaking any repairs,
always disconnect the extractor hood from
the electricity supply.
Length of the connecting cable: 1.30 m.
If it is necessary to wire the extractor
hood directly into the mains:
The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such
devices include circuit breakers and
contactors.
This extractor hood corresponds to EC
regulations concerning RF interference
suppression.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch DHI 605 B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch DHI 605 B in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 4,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info