Service menu | 7
Table 3 Settings in the system data menu
6.2 Heating circuit menu
Settings for the heating zone are made in this menu.
NOTICE:
Risk of damaging or destroying the screed!
If an underfloor heating system is installed, observe the
maximum flow temperature recommended by the
manufacturer.
Table 4 Settings in the heating zone menu
Frost protection
The setting by room temp offers sufficient frost protection
only if all the piping in the insulated building envelope is run in
the “warm area” (no reliable frost protection if the piping is run
in façades, for example).
6.3 DHW menu
Settings for water heating are made in this menu. A contractor
can set a hot water temperature higher than 60 °C. Only
available with EMS 2-BUS.
WARNING:
Risk of scalding from hot water!
If thermal disinfection has been set to avoid legionella (the
DHW is heated once Thursday night at 02:00 to 70 °C), or the
maximum storage temperature has been set to above 60 °C:
Inform all people concerned and make sure that a mixer is
installed.
Table 5 Settings in the hot water menu
6.4 Function test menu
The system pump can be tested using this menu.
Table 6 Settings in the function test menu
6.5 Info menu
Heating system settings and measurements are displayed in
this menu. Changes are not possible.
Recirculation NO: The DHW circulation pump cannot be
controlled by the heat source.
YES: The DHW circulation pump can be
controlled by the heat source.
Reset all NO: The current settings have been
retained.
YES: The factory settings are being restored
(except time and date).
Menu item Control range: Function description
Max. Suppl.T. 30 ... 48 ... 60 °C (example of underfloor
heating system): Maximum flow temperature
PID charact. Fast: Fast control characteristic, such as
when there is a small heating water quantity
in the air heating
Medium: Medium control characteristics, for
example with radiator heating
Slow: Slow control characteristics, for
example with underfloor heating system
Opt. pump run ON: The heating pump runs as little as
possible on the basis of the flow temperature
OFF If the system has more than one heat
source installed or a buffer cylinder is
installed, this function must be deactivated.
Frost protect
(only available
with 2-wire
BUS/EMS 2-
BUS)
OFF: Frost protection off
by room temp: Frost protection is
deactivated/activated on the basis of the
temperature selected here
DHW priority ON: DHW heating is activated, the heating is
interrupted
OFF: DHW heating is activated, parallel
operation with heating
Menu item Control range: Function description
Menu item Control range: Function description
Max. DHW
temp
60 ... 80 °C: The set value is the upper limit for
the desired hot water temperature
Menu item Control range: Function description
Activation NO: All actuators return to the same position
as before activating the test.
YES: All actuators in the system switch to the
test mode.
System pump 0 (in %): Heating pump not running (switched
off).
100 (in %): Heating pump running at
maximum speed.
Menu item Possible values: Description
Appl. oper. ON: Burner in operation
Off: Burner not operating
Appl.set flow 20 ... 90 °C: Flow temperature required at
the heat source (set temperature)
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch CR 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch CR 50 in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch CR 50

Bosch CR 50 User Manual - English - 12 pages

Bosch CR 50 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info