Electrical connection
Condens 7000 WP – 6721841195 (2022/01)
18
6.10 Connecting an expansion vessel
For the boiler and the system to function correctly, the right expansion
vessel must be selected.
Determine the size and pre-charge pressure of the expansion vessel
by referring to EN 12828.
Remove the cap from the connection point [1].
Connect the connecting pipework of the expansion vessel to the
connection point.
Fig. 20 Connecting an expansion vessel
6.11 Installing the insulation (accessory)
Insulating parts are available for the connection set of this boiler.
If the boiler is placed on the base frame, the insulation consists of
several panels. In the case of wall-mounted installation, the insulation
consists of 1 piece which is fastened underneath the boiler.
For more information, refer to worcester-bosch.co.uk or you will find
the relevant addresses on the rear of this document.
7 Electrical connection
CAUTION
Electric shock.
Disconnect the boiler from the power supply before working on
electrical parts.
NOTICE
Electrical short circuit due to incorrect cabling.
Only use original cables if they need to be replaced.
All 230 VAC connections in the boiler must be established using the
cable type H05VV-F 3 x 0.75 mm2 or NYM-J 3 x 1.5 mm2.
All 24 VAC connections in the boiler must be established using a 2-
wire power cable with 0.4 – 0.8 mm2 cross-section.
It must be possible to reach mains plug and therefore also the socket
(230 V AC, 50 Hz) at all times for commissioning of the boiler. The
socket must be earthed.
When establishing the electrical connection, also refer to the
documentation of the accessory to be connected and the wiring
diagram (§ 15.1, p. 46).
7.1 Handling printed circuit boards
Printed circuit boards with control electronics are very sensitive to
electrostatic discharge (ESD). To prevent damage to the components,
exercise utmost caution.
CAUTION
Damage due to electrostatic charge!
Wear an earthed wristband when handling unenclosed PCBs.
Fig. 21 Wrist strap
The damage is not normally immediately apparent. A PCB may function
perfectly during commissioning and problems often only arise later on.
Charged objects are only a problem if they are in the vicinity of the
electronics. Before starting work, ensure a safe distance of at least 1 m
from foam rubber, protective film and other packaging materials,
clothing made of synthetic fibres (e.g. fleece pullovers) and similar
items.
An earthed wrist strap offers good ESD protection when working with
electronics. This wrist strap must be worn when opening the screened
metallic bag/packaging or prior to exposing a fitted PCB. The wrist strap
must be worn until the PCB has been placed inside its screened
packaging or has been connected inside the closed control cabinet.
Replaced PCBs that are returned must be handled in this way.
7.2 Opening the top cover
The burner control unit and terminal strip for electrical components are
located under the top cover.
Open the top cover by unfastening the retaining screws [1].
Fig. 22 Opening the top cover
0010034327-001
1.
6 720 614 366-24.1I
0010033907-002
2.
1
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Condens GC7000WP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Condens GC7000WP in the language / languages: English as an attachment in your email.

The manual is 15.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Condens GC7000WP

Bosch Condens GC7000WP User Manual - English - 12 pages

Bosch Condens GC7000WP Installation Guide - German - 60 pages

Bosch Condens GC7000WP User Manual - German - 12 pages

Bosch Condens GC7000WP Installation Guide - Dutch - 56 pages

Bosch Condens GC7000WP User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info