Compress 7001i/7400i AW AWE – 6721835320 (2021/09)
20
4.1.5 Moisture in cooling mode
NOTICE
Insufficient condensate insulation
Moist near the components of the heating system.
Shut of the heating system and contact retailer/installer if moist or
condensate is found near any of the heating system components.
4.1.6 Checking the safety valves
The safety valves should be checked 1-2 times each a year.
Water is expelled from the safety valve during heat-up. Never close the
safety valve.
The safety valve should only let water out if the maximum pressure is
exceeded. Contact the installer if water is coming from the safety
valve at pressures below 2 bar.
The drainage hose from the safety valve shall be discharged into the
sewage / floor well.
4.2 Heat pump (outdoor unit)
The following inspection and maintenance steps are carried out several
times per year in order that the heat pump's maximum output will be
maintained:
Housing (casing)
Cleaning of the evaporator
▶Snow and ice
▶Cleaning of the condensation catch pan
4.2.1 Housing (casing)
Dust and other dirt particles concentrate in the heat pump's outdoor unit
over time.
Remove dirt and leaves from the heat pump with a brush.
If required, clean the outside with a damp cloth.
Spot repair cracks and damage on the casing with anti-corrosive
paint.
Standard car wax can be applied to protect the paint.
4.2.2 Evaporator
Any layers of dust or dirt, for example, deposited on the surface of the
evaporator must be removed.
CAUTION
The aluminium fins are thin and sensitive.
They can be damaged easily due to careless handling.
▶Never use hard objects.
Never rub the fins directly with a cloth.
Wear protective gloves.
Never use water pressure that is too high.
Cleaning of the evaporator:
Spray detergent on the evaporator fins on the back of the heat pump.
Rinse off coatings and detergent with water.
In some regions, washing-up liquid must not be flushed into gravel beds.
If the condensate tube discharges into a gravel bed:
Remove the flexible condensate tube from the drain pipe prior to
cleaning.
Collect the washing-up liquid in a suitable container.
Reconnect the condensate tube after cleaning.
4.2.3 Snow and ice
In certain geographical regions or during periods of heavy snow, snow
can get stuck on the back and the roof of the heat pump. Make sure to
clear the snow to prevent icing-up.
Carefully brush the snow off the fins.
Clear the snow off the roof.
Hot water can be used to rinse off the ice.
Moisture can form under the heat pump due to condensate not falling
into the condensation catch pan. This is normal and no special action is
required.
If the heat pump has sound insulation, ice can form. In this case there is
risk of falling.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Compress 7400i AW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Compress 7400i AW in the language / languages: English as an attachment in your email.

The manual is 4.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Compress 7400i AW

Bosch Compress 7400i AW Installation Guide - German - 28 pages

Bosch Compress 7400i AW User Manual - German - 28 pages

Bosch Compress 7400i AW Installation Guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info