743381
16
Zoom out
Zoom in
Previous page
1/28
Next page
Operation
Compress 7001i/7400i AW AWE – 6721835320 (2021/09)
16
Table 14 Settings for holiday programs
3.3.5 Settings for other systems or devices
If other specific systems or devices are installed in the system, additional
menu items will be available. Depending on which system or device is
being used and the associated assemblies or components, various
settings can be made. Observe the additional information on the settings
and functions in the technical documentation for the relevant system or
device.
Settings for a swimming pool
Menu: Pool
Table 15 Settings for pool heating
Settings for smart grid
This menu is only available if a smart grid system is installed.
Table 16 Settings in the smart grid data menu
Settings for a photovoltaic system
Make the photovoltaic (PV) specific settings in this menu. Select if the
available energy should be used for Heating or DHW.
If photovoltaic energy is available and a buffer cylinder is installed with all
heating circuits mixed, the buffer cylinder will be heated to the heat
pump maximum temperature.
Menu: PV system
Table 17 Settings in the PV system data menu
Settings for the energy manager
Make the energy manger (EM) specific settings in this menu.
Menu: Energy manager
Table 18 Settings in the EM system data menu
3.3.6 General Settings
Menu: Settings
DHW DHW settings for the selected DHW systems during
the holiday period.
If [Off] is set, no DHW at all will be available
during the holiday period.
If [Off + therm. disinfection on] is set, DHW
heating is deactivated but thermal disinfection is
still carried out as normal either once a week or
once a day.
Note: If the holiday is spent at home, the DHW
systems must not be selected under [Selection of
htg circ./DHW] to ensure DHW remains available.
Delete Delete all settings for the selected holiday program
Menu item Description
Switch on pool
heating
This setting enables the pool heating when it is
activated.
Pool
temperature
The water in the pool is heated to this temperature.
Allow add. heater
for pool
This setting allows the auxiliary heater to supply
heating for the pool if the heat pump cannot reach
the set temperature.
Menu item Control range: Function description
Heating The energy available in the smart grid is used for heating, if
the system is in heating mode.
[Selectable peak]: 0...5 °C
Set how much the room temperature may be increased.
[Forced peak]: 2...5 °C
Set how much the room temperature is forced to increase.
DHW The energy available in the smart grid is used for DHW.
[Selectable peak]: [Yes] | [No]
If enabled the DHW is heated to the temperature set for
DHW operating mode [Always on - DHW comfort]. No
heating is done if the holiday program is active.
Menu item Description
Menu item Control range: Function description
Heating peak The energy available in the PV system is used for heating, if
the system is in heating mode.
Set how much the room temperature may be increased
[0...5] °C.
DHW peak The energy available in the PV system is used for DHW.
[Yes] | [No]
If enabled the DHW is heated to the temperature set for
DHW operating mode [Always on - DHW comfort]. No
heating is done if the holiday program is active.
Cooling setback
mode
The energy available in the PV system is used for cooling, if
the system is in cooling mode.
Set how much the room temperature may be decreased
[-5...0] °C.
Only cool with PV Cooling mode is activated only if energy is available in the
PV system.
[Yes] | [No]
If enabled the room temperature is decreased to the
temperature set for cooling operating mode. No cooling is
done if the holiday program is active.
Menu item Control range: Function description
Heating peak The energy available in the energy management system is
used for heating, if the system is in heating mode.
Set how much the room temperature may be increased
0...5 °C.
Only cool with EM Cooling mode is activated only if energy is available in the
energy management system.
[Yes] | [No]
If enabled the room temperature is decreased to the
temperature set for cooling operating mode. No cooling is
done if the holiday program is active.
Menu item Description
Language Language of the display texts
Time format Switch the format for display of the time of day
between 24-hour and 12-hour format.
Time of Day Set actual time. All time programs and thermal
disinfection run according to this time.
Date format Change the format of the date.
Date Set actual date. The holiday program, for example,
runs based on this date. The current day of the week
is also determined based on this date; this affects
the time programs and thermal disinfection,
for example.
Auto. time
switchover
Activate or deactivate the automatic changeover
between summer and winter time. If [Yes] is set, the
time of day is automatically changed (from 02:00 to
03:00 on the last Sunday in March and from 03:00
to 02:00 on the last Sunday in October).
Display contrast Change the contrast (for improved clarity).
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Compress 7400i AW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Compress 7400i AW in the language / languages: English as an attachment in your email.

The manual is 4.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Compress 7400i AW

Bosch Compress 7400i AW Installation Guide - German - 28 pages

Bosch Compress 7400i AW User Manual - German - 28 pages

Bosch Compress 7400i AW Installation Guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info