6
Do not set a too low temperature for cooling. Cooling will also
consume energy.
Vent the room correctly
Open the windows fully for a short period instead of leaving them ajar.
Leaving the windows ajar will let the heated air out of the room constantly
without increasing the air quality. Close the thermostatic valves or lower
the heating setting on the room controller while the room is vented.
3Operation
WARNING
Material damage from frost!
The heating or auxiliary heater may be irreparably damaged by frost.
Do not start the indoor unit if there is a possibility of the heating or
auxiliary heater being frozen.
3.1 Control unit
The user interface HPC 410 controls max. 4 heating circuits individually
in one of the respective control modes:
Outdoor-temp.-compensated
the flow temperature is adjusted based on the outside
temperature according to an optimised heating curve.
Outdoor-temp.-compensated with low end1)
the flow temperature is adjusted based on the outside
temperature according to a simplified heating curve.
For both of the control modes a room controller may be installed in the
reference room to allow the influence of the measured and required
room temperature. The heating curve is then adjusted accordingly.
The user interface HPC 410 is installed in the appliance and cannot be
used as room controller. Ask your contractor for available room
controllers.
Rule of thumb for outdoor-temp-compensated control with influence of
room temperature: the thermostatic valves in the reference room (the
room in which the remote control is installed) must be fully open!
The cooling function is not available in Belgium or Denmark.
The cooling menu items mentioned in this manual may be hidden if the
installed system is not suitable for cooling.
The electric booster or additional heater are not available for normal
operation in Denmark. The heater are however allowed to run in fault
mode, for extra DHW and thermal disinfection.
Depending on the software version of the user interface, the texts shown
in the display may differ from the texts in these instructions.
The adjustment ranges, default settings and functional scope may differ
from the information in these instructions, depending on the system
installed at the site.
If 2 or more heating circuits are installed, settings for different
heating circuits are available and are necessary.
If special system components and modules are installed (e.g.
MS 200 solar module, pool module MP 100), corresponding settings
are available and necessary.
If certain types of heat source are installed, additional settings may
be available and necessary.
3.1.1 Operation after power failure
At electric power failure or periods with disconnected heat source, no
settings are lost. The control unit will restart when the power is restored.
It is possible that time and date may need to be reset. No other settings
are needed.
3.2 Control panel
3.2.1 Overview of control elements and symbols
Fig. 4 Control elements
[1] fav key: calls up the favourites menu
[2] extra DHW key: starts extra DHW charging
[3] DHW key: set the operating mode for DHW heating
[4] menu key: main menu (press briefly)
[5] info key: info menu or further information about the current
selection
[6] d key: returns to previous menu or discards a value (press
briefly); returns to the standard display (hold down)
[7] Selector: select (turn) and confirm (press)
If the display lighting is off, only the lighting goes on when the selector is
pressed for the first time. When the selector is turned and another
control element is pressed at the same time, the lighting is switched on
in addition to the effect described. The descriptions of the steps to be
carried out by the operator in these instructions always assume that the
lighting is activated. If no control element is actuated, the lighting turns
off automatically (after approx. 30 s with the standard display, after
approx. 30 min in the menu, after 24 h in the event of a fault).
Fig. 5 Symbols in the standard display (example display)
1) This setting is not available in Finland or Sweden
0010032819-001
fav
menu
info
5
6
7
4
2
3
1
6 720 811 136-901.1O
6
1
3
7
2
4
5
5
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Compress 7400i AW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Compress 7400i AW in the language / languages: English as an attachment in your email.

The manual is 4.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Compress 7400i AW

Bosch Compress 7400i AW Installation Guide - German - 28 pages

Bosch Compress 7400i AW User Manual - German - 28 pages

Bosch Compress 7400i AW Installation Guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info