16
Settings for smart grid
This menu is only available if a smart grid system is installed.
Table 17 Settings in the smart grid data menu
Settings for a photovoltaic system
Make the photovoltaic (PV) specific settings in this menu. Select if the
available energy should be used for Heating or DHW.
If photovoltaic energy is available and a buffer cylinder is installed with all
heating circuits mixed, the buffer cylinder will be heated to the heat
pump maximum temperature.
Menu: PV system
Table 18 Settings in the PV system data menu
Settings for the energy manager
Make the energy manger (EM) specific settings in this menu.
Menu: Energy manager
Table 19 Settings in the EM system data menu
3.3.6 General Settings
Menu: Settings
Table 20 General Settings
Menu item Control range: Function description
Heating The energy available in the smart grid is used for heating, if
the system is in heating mode.
[Selectable peak]: 0...5 °C
Set how much the room temperature may be increased.
[Forced peak]: 2...5 °C
Set how much the room temperature is forced to increase.
DHW The energy available in the smart grid is used for DHW.
[Selectable peak]: [Yes] | [No]
If enabled the DHW is heated to the temperature set for
DHW operating mode [Always on - DHW comfort]. No
heating is done if the holiday program is active.
Menu item Control range: Function description
Heating peak The energy available in the PV system is used for heating, if
the system is in heating mode.
Set how much the room temperature may be increased
0...5 °C.
DHW peak The energy available in the PV system is used for DHW.
[Yes] | [No]
If enabled the DHW is heated to the temperature set for
DHW operating mode [Always on - DHW comfort]. No
heating is done if the holiday program is active.
Cooling setback
mode
The energy available in the PV system is used for cooling.
[Yes] | [No]
If enabled the room temperature is decreased to the
temperature set for cooling operating mode. No cooling is
done if the holiday program is active.
Only cool with PV Cooling mode is activated only if energy is available in the
PV system.
[Yes] | [No]
If enabled the room temperature is decreased to the
temperature set for cooling operating mode. No cooling is
done if the holiday program is active.
Menu item Control range: Function description
Heating peak The energy available in the energy management system is
used for heating, if the system is in heating mode.
Set how much the room temperature may be increased
0...5 °C.
Only cool with EM Cooling mode is activated only if energy is available in the
energy management system.
[Yes] | [No]
If enabled the room temperature is decreased to the
temperature set for cooling operating mode. No cooling is
done if the holiday program is active.
Menu item Description
Language Language of the display texts
Time format Switch the format for display of the time of day
between 24-hour and 12-hour format.
Time of Day Set actual time. All time programs and thermal
disinfection run according to this time.
Date format Change the format of the date.
Date Set actual date. The holiday program, for example,
runs based on this date. The current day of the week
is also determined based on this date; this affects
the time programs and thermal disinfection,
for example.
Auto. time
switchover
Activate or deactivate the automatic changeover
between summer and winter time. If [Yes] is set, the
time of day is automatically changed (from 02:00 to
03:00 on the last Sunday in March and from 03:00
to 02:00 on the last Sunday in October).
Display contrast Change the contrast (for improved clarity).
Warning sound
blocked
If a buzzer has been installed a warning sound is
emitted as soon as an alarm occurs. The warning
sound can be suppressed at a settable time interval.
Reduced DHW
temp.
Setting for the reduced DHW mode. If [Yes] is set,
the DHW temperature is reduced if there are a
compressor fault. The function is used to reduce the
use of the auxiliary heater.
DHW temp.
correction
Correction of the DHW temperature displayed by
the user interface by up to ± 10 °C.
Time correction Time correction of the internal clock of the user
interface in s/week.
Standard display Settings for the display of additional temperatures in
the standard display.
Internet
password
Reset the personal password for the Internet
connection (only available if a communication
module is installed). The next time you log in, e.g.
using an App, you will automatically be prompted to
assign a new password.
Internet Make settings for the Internet connection (only
available if a communication module is installed).
[Establish connection]
[Pairing-Status]
[Activate hotspot]
[Activate WPS]
[Terminate connection]
[Connected network]
[Terminate connection]
Low-noise
operation
If activated the heat pump will run in reduced sound
operation during the set time period.
[Low-noise operation of]: set the start time for
the low noise operation.
[Low-noise operation until]: set the stop time for
the low noise operation.
[Min. outside temp.]: Below this outdoor
temperature the heat pump switches over to
normal operation.
Reset Reset all settings to the values set at commissioning.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Compress 7000 AWM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Compress 7000 AWM in the language / languages: English as an attachment in your email.

The manual is 6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info