809317
35
Zoom out
Zoom in
Previous page
1/44
Next page
Technical information
35
Compress 3400i AWS – 6721852066 (2023/01)
The power supply cable of the Installer Module of the indoor unit has an
integrated fuse. In case of damage, the power supply cable [6] must be
replaced (see spare part list manual).
Max load for relay outputs PW2, PK2, VW1, PC1: 2A, cos φ > 0.4.
Maximum load for CUHP inst.: 6.3A
Note regarding input I1 (connection 13, 14) and I4 (connection 15,16).
The contact on the component or relay that is connected to this input
must be suitable for 5V and 1mA.
Note regarding [1]:
Coding switches A and P must not be adjusted! Otherwise malfunctions
and faults will occur.
Important: check the coding when a replacement part is used.
Note regarding [4]: to avoid reflection of messages in the CAN-BUS, the
CAN terminator switch should be switched on.
11.4.2 CAN & EMS BUS
Fig. 36 CAN and EMS connections
Continuous line = connection made at the factory
Dashed line = connection made during installation:
[A] Indoor unit
[B] Outdoor unit
[1] Control unit (user interface)
[2] Coding switch setting for A and P encoders (A=0, P=1)
[3] Installer module
[4] Room controller (accessories)
[5] EMS module (accessory)
[6] Connect-Key K 30 RF (accessory)
[7] Outdoor unit
[8] Outdoor unit terminals
_______________ Connected at factory/connected
during installation
_ __ ___ ___ __ Accessories
12
3
4
5
A
6
B
7
0010036950-001
8
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Compress 3400i AWS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Compress 3400i AWS in the language / languages: English as an attachment in your email.

The manual is 7.89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Compress 3400i AWS

Bosch Compress 3400i AWS User Manual - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info