613833
15
Zoom out
Zoom in
Previous page
1/24
Next page
6 720 607 800 (2016/03)
Installation | 15
Solar installations
Fig. 12 Solar installation
[1] Cold water
[2] Hot water
[3] Thermostatic valve
[4] Expansion vessel
[5] Safety unit
6.1 Important
Before installation, consult the gas company and current
legislation regarding gas appliance and site ventilation.
Install a gas shut-off tap as close to the appliance as
possible.
After connection to the gas main, the appliance should be
carefully cleaned and tested for leaks; To avoid damage
from excess pressure in the automatic gas regulator, this
should be carried out with the gas valve shut.
Ensure that the appliance installed is suitable for the type
of gas provided.
Ensure that the flow and pressures for the regulator
installed are those indicated for the consumption of the
appliance (see technical data in table 5).
6.2 Selection of location for installation
Considerations relevant to location
Fulfil requirements specific to each country.
The heater must not installed above a source of heat.
Respect the minimum installation measurements indicated
in Fig. 13.
▶The appliance must not be installed in sites where the
ambient temperature is susceptible to drop below 0 °C.
Where there is a risk of freezing, disconnect and empty the
appliance (Fig. 6).
ApplIances type B
Do not install the appliance in the rooms with a volume less
than 8m
3
(do not consider the volume of the furnishings, as
this does not exceed 2m
3
).
Air intake (appliances type B)
The room earmarked for the installation of the appliance must
have an area of air supply as per the table.
The minimum requirements are listed above, but the specific
requirements of each country have to be respected.
Combustion air
The air admission grill must be located in a well ventilated
area.
To avoid corrosion, products such as solvents, inks,
inflammable gases, glue or domestic detergents containing
halogenic hydro-carbons or any product that might
provoke corrosion must not be stored near the air
admission grill.
Installation, electrical connection, gas
installation, connection of inlet and exhaust
pipes and initial startup must be realized
exclusively by authorized personnel.
The heater can only be used in the countries
indicated on the appliance type plate.
CAUTION: Assure that inlet water into the
appliance does not exceed 60 °C, for
example when used as a backup for solar
installations.
A 3-way valve or thermostatic valve
(adjusted to values lower than 60 °C)
must be installed before the appliance if
inlet water temperature exceeds this
limit.
Assure that the installation contains an
expansion vessel.
For outlet temperature greater then 45 °C we
recommend the use of a descaling system.
2
2
1
3
6720608999-11.6V
T
5
4
Appliance Minimum useful area
WT 11... 60 cm
2
Table 14
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Celsius WT11 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Celsius WT11 in the language / languages: English as an attachment in your email.

The manual is 1,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Celsius WT11

Bosch Celsius WT11 User Manual - German - 28 pages

Bosch Celsius WT11 Usermanual and installation guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info