79212
12
Zoom out
Zoom in
Previous page
1/86
Next page
EURO • Printed in England • BA F016 L69 835 • AQUATAK 100 • GB • OSW 09/01
English - 1
Before start-up please read these instructions!
Before using the machine please read the operating in-
structions for your unit and comply in particular with
these safety instructions.
The warning and information signs attached to the unit provide
important information for safe operation.
Apart from the information in the operating instructions comply
with the general safety regulations and regulations for the pre-
vention of accidents.
Power Supply
The voltage indicated on the rating plate must correspond to the
voltage of the power source.
Class 1 units may only be connected to properly earthed power
sources.
We recommend that this equipment is only connected into a
socket which is protected by a circuit-breaker that would be actu-
ated by a 30 mA residual current.
Only use or replace power supply cables for this unit which corre-
spond to the types indicated by the manufacturer. See the operat-
ing instructions for the order no. and types.
If the plug is damaged, pay attention to the following:
Plugs and sockets confirming to BS 4243 or BS 196 should be
used wherever practicable. Domestic pattern plugs to BS 1363 are
not recommended but if their use is essential those which have
barriers or moulded channels inside should be selected so that if
the earth continuity conductor is pulled out of its terminal it is un-
likely to be able to touch the phase terminal of the fuse carrier. Do-
mestic pattern plugs to BS 546 should not be used. The wiring of
the plug should leave more slack in the earth continuity conductor
than in the other cores, so that it is not the first core to be pulled
out of its terminal should the cord grip fail. Plugs which have good
grips capable of maintaining a firm hold on the cable sheath
should be selected. In general, additional means should be pro-
vided to relieve stress on cable terminations in the plug. For exam-
ple, additional cable clamps should be fitted or a substantial chain
could be used to tether the machine to a fixed point.
Plugs and sockets situated near the work site or outdoors should
be to class IP 55 of BS 5490 to provide adequate protection
against ingress of water, etc. and cable entries require effective
sealing. Rubber shrouds should be provided over cable glands.
Drip-proof (class IP X2 of BS 5490) plugs and sockets to BS 4343
are suitable for use indoors where the plug is away from the water
spray area where the appliance is in use.
Never touch the mains plug with wet hands.
Do not run over, crush or pull the power supply cable or extension
lead, otherwise it may be damaged. Protect the cable from heat,
oil and sharp edges.
The extension lead must have a cross section in accordance with
the operating instructions and be protected against splashed wa-
ter. The connection must not be in water.
When replacing couplings on the power supply cable or extension
lead the spray water guard and mechanical stability must remain
in tact.
Water connection
Comply with the regulations of your water supply company.
All connecting hoses must have properly sealed joints.
The high-pressure hose must not be damaged (danger of burst-
ing). A damaged high-pressure hose must be replaced immedi-
ately. Only use hoses and connections recommended by the man-
ufacturer.
Application
Before use, check that the unit and operating equipment are in
perfect condition and are safe to operate. Do not use the unit if it
is not in perfect condition.
Never draw in solvent-containing liquids, undiluted acids or sol-
vents! This includes petrol, paint thinners heating oil. The sprayed
vapour is highly flammable, explosive and toxic; also acetone, un-
diluted acids and solvents as these corrode the materials used on
the unit.
The appropriate safety regulations must be observed when using
the unit in dangerous area (e.g. petrol stations). It is forbidden to
operate the unit is potentially explosive locations.
The unit must be placed in a solid base.
Only use detergents recommended by the manufacturer and com-
ply with the application, disposal and warning instructions of the
detergent manufacturers.
All current-conducting components in the working area must be
protected against splashed water.
The gun trigger must not be jammed in position during operation.
Suitable protective clothing must be worn if necessary to protect
against splashing from some parts.
Never direct the water jet at people, animals, the unit or electric
components.
Vehicle tyres/tyre valves may only be cleaned from a minimum
distance of 30 cm, otherwise the vehicle tyre/tyre valve could be
damaged by the high-pressure jet. The first indication of this is a
discoloration of the tyre. Damaged vehicle tyres/tyre valves can be
deadly dangerous.
Materials containing asbestos and other materials which contain
substances which are hazardous to your health must not be
sprayed.
Only use detergents which have been approved by the manufac-
turer of the unit.
Detergents must not be used undiluted. The products are safe to
use as they contain no acids, alkalis or substances which are det-
rimental to the environment. We recommend that the detergents
are kept out of the reach of children. If detergent comes into con-
tact with the eyes wash immediately with plenty of water and if
swallowed contact a doctor immediately.
Do not lift up the bonnet while the motor is running.
Operation
The operator must use the unit in accordance with the regulations.
He/she must take local conditions into account and be aware of
other people, especially children, when operating the unit.
The unit may only be used by authorised persons who have re-
ceived training or have demonstrated their ability to operate the
unit. The unit must not be operated by children or juveniles (dan-
ger of accidents due to incorrect use of the unit).
The unit must never be left unsupervised while the motor is run-
ning.
The water jet from the high-pressure nozzle produces a recoil on
the gun. You should therefore hold the gun and spray lance firmly.
Transport
Switch of the motor and secure the unit before transporting.
Maintenance
Switch off the unit prior to all cleaning and maintenance work and
before replacing components. Pull out the mains plug if the unit is
mains-operated.
Repairs may only be carried out by authorised BOSCH Service
Centres.
Commercial units which may be used in different locations are
subject to a safety check according to VDE 0701.
Accessories and spare parts
Only use accessories and spare parts which have been approved
by BOSCH. Original accessories and spare parts guarantee that
the unit can be operated safely and without any breakdowns.
Safety Notes
F016 L69 835.book Seite 1 Donnerstag, 6. September 2001 12:56 12
12 • F016 L69 835 • TMS • 21.08.01
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Aquatak 100 Compact at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Aquatak 100 Compact in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info