697454
136
Zoom out
Zoom in
Previous page
1/170
Next page
136 en | Address programming AMAX panel
2019.08 | 11 | F.01U.309.277 Installation Manual Bosch Security Systems B.V.
Value range: 00 = master keypad, 01 - 16 = area 01 - 16, 99 = not used
Notice!
The system supports up to 16 master keypads. When the master keypad is not switched to
the corresponding area, no arming/disarming, bypass and alarm reset operations can be
performed on the master keypad. Operations can only be performed in the area when the
master keypad is switched to the corresponding area.
8.5.2 Area timing programming
Exit and entry delay time
Area Exit Delay
Address
Default Entry Delay
Address
Default Entry Delay
2 Address
Default
1 0785 - 0787 45 0788 - 0790 30 0791 - 0793 30
2 0794 - 0796 45 0797 - 0799 30 0800 - 0802 30
3 ** 0803 - 0805 45 0806 - 0808 30 0809 - 0811 30
4 ** 0812 - 0814 45 0815 - 0817 30 0818 - 0820 30
5 ** 0821 - 0823 45 0824 - 0826 30 0827 - 0829 30
6 ** 0830 - 0832 45 0833 - 0835 30 0836 - 0838 30
7 ** 0839 - 0841 45 0842 - 0844 30 0845 - 0847 30
8 ** 0848 - 0850 45 0851 - 0853 30 0854 - 0856 30
9 * 0857 - 0859 45 0860 - 0862 30 0863 - 0865 30
10 * 0866 - 0868 45 0869 - 0871 30 0872 - 0874 30
11 * 0875 - 0877 45 0878 - 0880 30 0881 - 0883 30
12 * 0884 - 0886 45 0887 - 0889 30 0890 - 0892 30
13 * 0893 - 0895 45 0896 - 0898 30 0899 - 0901 30
14 * 0902 - 0904 45 0905 - 0907 30 0908 - 0910 30
15 * 0911 - 0913 45 0914 - 0916 30 0917 - 0919 30
16 * 0920 - 0922 45 0923 - 0925 30 0926 - 0928 30
000-999 seconds 000-999 seconds, EN=045
seconds
000-999 seconds, EN=045
seconds
* AMAX 4000
** AMAX 3000 / 3000 BE / 4000
Entry and exit delay time audible
Option Address Default
Area 1
(01 = entry time (STAY) for area keypad,
02 = exit time (STAY) for area keypad,
1714 - 1715 15
136


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX panel 4000 EN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX panel 4000 EN in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX panel 4000 EN

Bosch AMAX panel 4000 EN Quick start guide - German - 76 pages

Bosch AMAX panel 4000 EN Quick start guide - Dutch - 76 pages

Bosch AMAX panel 4000 EN Installation Guide - Dutch - 190 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info