AMAX panel Settings | en 89
Bosch Security Systems B.V. Installation Manual 2019.08 | 11 | F.01U.309.277
The output is reset when the 24h alarm is reset or the output time ends.
32 - 24h panic alarm
This output is operated when a 24h panic alarm occurs. This output works only on zone type
10.
The output is reset when the 24h panic alarm is reset or the output time ends.
33 - Medical Alarm
This output is operated when a medical alarm occurs.
The output is reset when the medical alarm is reset or the output time ends.
34 - RF power fault
The output is operated in the following cases:
The battery of the RF transmitter is low.
The battery of the RF repeater is low.
An AC power fault of the RF repeater occurs.
The output is reset in the following cases:
The RF power is normal and the system is reset.
The programmed output time ends.
35 - Follow zone
This output imitates the zone state. The output is operated according to the corresponding
zone.
The output is reset according to the corresponding zone.
36 - Schedule
This output is operated when a schedule is enabled.
The output is reset when the schedule is reset or the output time ends.
Output mode
Three different output modes are available.
0 - Continuous output
The output is continuous, the level is high.
1 - Pulse output
The output occurs in pulses, the period is 1 second.
2 - Continuous inverted output
The output is continuous, the level is low (level is high in idle state). When PO-1 or PO-2 is set
to inverted, supervision is disabled for these outputs.
Output time
Each output is operated for a specific time and resets at the end of output time.
The actual output time of system audio alarm, system alarm, and follow zone event is related
to the ringing of the alarm siren.
The possible output time value range is 0 - 999 seconds.
89


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX panel 4000 EN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX panel 4000 EN in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX panel 4000 EN

Bosch AMAX panel 4000 EN Quick start guide - German - 76 pages

Bosch AMAX panel 4000 EN Quick start guide - Dutch - 76 pages

Bosch AMAX panel 4000 EN Installation Guide - Dutch - 190 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info