74 en | Settings AMAX panel
2019.08 | 11 | F.01U.309.277 Installation Manual Bosch Security Systems B.V.
Displaying areas in a LED/LCD keypad
For any area, the logic numbers of the zones are displayed on the LED/LCD keypad and logic
numbers or zone names of the zones are displayed on the keypad instead of actual physical
numbers. For example: The zones 1, 2, and 3 of 1 area or area 1 displayed on the keypad are
actually zones 20, 31, and 37.
6.4.2 Entry/exit timing
The AMAX panel supports separate entry and exit delay times for each area.
Exit delay
The programming range is 0 - 255 seconds. In the mode of system arming, the keypad will
beep during exit and will make continuous long beep sound in the last 10 seconds to notify
the exit time is coming to an end.
Entry delay 1
The programming range is 0 - 255 seconds. Entry delay time starts when a delay zone 1 (zone
type 03, 04, 05, 06) is triggered in armed state.
Entry delay 2
The programming range is 0 - 255 seconds. Entry delay time starts when a delay zone 2 (zone
type 07, 08, 09, 10) is triggered in armed state.
Entry and exit delay time audible
This option defines whether an entry or exit delay time is silent or audible. One or more of the
following entry and exit delay time scenarios can be selected individually for audible or silent
indication of entry and exit time.
Entry time (STAY) for area keypad
Exit time (STAY) for area keypad
Entry time (STAY) for master keypad
Exit time (STAY) for master keypad
Entry time (AWAY) for area keypad
Exit time (AWAY) for area keypad
Entry time (AWAY) for master keypad
Exit time (AWAY) for master keypad
Per default, all entry and exit time scenarios are set to audible indication.
6.4.3 Common area
Area 1 can be used as an independent or a common area with other areas being subordinated.
If area 1 is a common area the following applies:
Only when all subordinate areas are armed, the common area can be armed.
If a subordinate area is in STAY arm mode, the common area is in STAY arm mode too.
If a subordinate area is disarmed, the common area will be disarmed too.
If any zones under common zones are triggered or in tamper status and forced arming is
disabled, the common area cannot be armed.
Common area indication
If area 1 is a common area, the following icons are used to indicate the status on the keypad:
Indication on keypad Description
COMM No event in common area, no open zones
COMM Ø Event in common area if force arming is
disabled for the zone, e.g. open zone
READY No event in area, no open zones
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX panel 4000 EN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX panel 4000 EN in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX panel 4000 EN

Bosch AMAX panel 4000 EN Quick start guide - German - 76 pages

Bosch AMAX panel 4000 EN Quick start guide - Dutch - 76 pages

Bosch AMAX panel 4000 EN Installation Guide - Dutch - 190 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info