AMAX panel Settings | en 59
Bosch Security Systems B.V. Installation Manual 2019.08 | 11 | F.01U.309.277
13 24-hour
14 Key AWAY toggle
15 Key AWAY on/off
16 Key STAY toggle
17 Key STAY on/off
18 24-hour panic
19 24-hour fire
20 24-hour fire with verification*
21 Tamper
22 Bold contact
23 External fault
24 Technical alarm
25 Reset
26 Instant report
* Only possible for AMAX 4000 zone 1
00 - Not used
If a zone is not used, program the zone type location to 0. An EOL resistor is not required if
this zone type is not used. This zone type never activates the sirens or the dialer.
01 - Instant
The instant zone type performs as described below:
1. Disarm:
Zone normal - no alarm / no report
Zone triggered - no alarm / no report
2. AWAY Arm:
Zone normal - no alarm / no report
Zone triggered - alarm / report
(Zone triggered during exit time no alarm / no report)
(Zone triggered during entry time alarm / report is delayed for 30 seconds or entry
time is expired, when system is disarmed before, no report)
3. STAY Arm:
Zone normal - no alarm / no report
Zone triggered - alarm / report
(Zone triggered during exit time no alarm / no report)
(Zone triggered during entry time alarm / report is delayed for 30 seconds / entry
time is expired, when system is disarmed before, no report) When zone is triggered,
not bypassed and system is forced to arm, a zone fault report is sent.
When the system is disarmed and zone is not restored before, a Zone fault restore
report is sent.
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX panel 4000 EN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX panel 4000 EN in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX panel 4000 EN

Bosch AMAX panel 4000 EN Quick start guide - German - 76 pages

Bosch AMAX panel 4000 EN Quick start guide - Dutch - 76 pages

Bosch AMAX panel 4000 EN Installation Guide - Dutch - 190 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info