697458
159
Zoom out
Zoom in
Previous page
1/170
Next page
AMAX panel Troubleshooting | en 159
Bosch Security Systems B.V. Installation Manual 2019.08 | 11 | F.01U.309.277
1. Report the keyfob battery fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
3 -Output Failure
Onboard Output 1-2 Fault
Condition:
An onboard output is in a short circuit or open circuit condition.
Restore:
4 Restore the onboard output to a normal condition and reset the fault. For more
information refer to Outputs, page 82.
Supervise:
1. Report the onboard output 1-2 fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
4 -Keypad Failure
Keypad 1-16 failure
Condition:
No communication between the panel and a keypad.
Restore:
4 Restore the communication between the panel and the keypad and reset the fault. For
more information refer to Keypad area, page 73.
Supervise:
1. Report the keypad fault to the configured destination programmed on address 124.
Slow flash FAULT indicator (refer to Keypad indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
5- System Failure
Date and Time not set
Condition:
Date and time is not set after the system is powered on.
Restore:
4 Program date and time and reset the fault. For more information refer to System setting,
page 77.
Supervise:
1. Report the date and time fault to the configured destination programmed on location
124.
2. Slow flash FAULT indicator (refer to Keypad indicators, page 8 for a detailed description)
3. No report to the AMAX panel system, when date and time setting is recorded in
nonvolatile memory and AMAX Panel is reset. The FAULT indicator is turned off when
there is no other system fault.
159


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX panel 2100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX panel 2100 in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX panel 2100

Bosch AMAX panel 2100 User Manual - English - 36 pages

Bosch AMAX panel 2100 Installation Guide - German - 186 pages

Bosch AMAX panel 2100 Installation Guide - Dutch - 184 pages

Bosch AMAX panel 2100 Quick start guide - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info