714552
9
Zoom out
Zoom in
Previous page
1/16
Next page
EN
9
Installation
www.bora.com
4 Installation
Observe all safety and warning information (see the
Safety section).
Follow the enclosed manufacturer’s information.
INFO The product must not be installed above
cooling devices, dishwashers, stoves, ovens,
washing machines or driers.
4.1 Checking the scope of delivery
Name Quantity
Recirculation unit 1 (UUE1) 1
Operating and installation instructions 1
Tab. 4.1 Scope of delivery
Check the scope of delivery for damage and make sure
it is complete.
If there are any missing or damaged parts, please
notify BORA After Sales Service.
Do not under any circumstances install parts which are
damaged.
Dispose of transport packaging in the proper manner
(see the Decommissioning and Disposal section).
4.2 Assembly instructions
Keep the airflow channels as short as possible.
Do not install the recirculation unit in floor units or
bodies with no separation from the doors or drawers
as the positive pressure could cause these to open of
their own accord.
The drawers, back panels and shelves in the floor unit
must be removable for maintenance and cleaning
purposes.
If the recirculation unit is installed in an adjacent room,
air recirculation must occur in the room in which the
vapour extraction system is installed so as not to
generate any low pressure.
4.3 Installing the recirculation unit
INFO A return flow aperture of > 500 cm
2
in the
plinth area must be provided for recirculation.
INFO The air duct diameter must be no less than
150 mm (176 cm
2
).
INFO With an air duct length of 50 cm, no corner or
bend should be installed before the fan module
(motor).
INFO Install straight duct pieces with a length of at
least 50 cm between the corners or bends.
4.3.1 Installing the recirculation unit
Compressed tape is installed on the recirculation
unit’s internal connection to enable this to be securely
attached.
Connect the duct with the recirculation unit’s ducting.
Evenly push the recirculation unit onto the ducting.
Remove the protective film from the Velcro fastener on
the outer side of the recirculation unit.
Use the Velcro fastener to prevent the recirculation
unit from slipping.
Stick the connections for the ducting sections to the
housing with an air tight join
UDB25 sealing tape can also be used for air-tight
installation (not included in the scope of delivery). The
UDB25 sealing tape (Universal accessory UDB25) can
be obtained from your BORA distributor.
4.3.2 Replacing the Universal recirculation
unit
Switch off the cooktop extractor as shown in the BORA
cooktop extractor operating instructions.
Open the revision option to access you appliance.
Loosen the appliance with the angle brackets.
Remove the appliance from the ducting.
Clean the ducting with a soft cloth and detergent or
water.
Install the replacement appliance as described in the
Installation section.
Check that all the duct connections are tight and
secure.
Check that the appliance functions correctly.
Do this by putting the cooktop extractor into operation
as shown in the BORA cooktop extractor operating
instructions.
Seal any possible leakages.
Re-check the tightness of the connections.
Seal the revision option.
Properly dispose of the used filter.
4.4 Handover to user
Once installation is complete:
Explain the main functions to the user.
Explain all safety-related aspects of operation and
handling to the user.
Provide the user with the accessories and the
operating and installation instructions for safe storage.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora UUE1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora UUE1 in the language / languages: English as an attachment in your email.

The manual is 0,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora UUE1

Bora UUE1 User Manual - German - 16 pages

Bora UUE1 User Manual - Dutch - 16 pages

Bora UUE1 User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info