Installation
www.bora.com
6 Installation
6.1.1 Simultaneous operation of the cooktop
extractor in the exhaust air mode and a
fireplace dependent upon the air supply
in the room
i National and regional laws and regulations must be
observed with regard to the exhaust duct design.
i A sufficient air supply must be ensured.
Fireplaces that depend on the air in the room (e.g. gas, oil,
wood or coal-fired heaters, continuous-flow water heaters,
instantaneous water heaters) draw in air from the room in which
they are installed and release the exhaust fumes into the outside
air via an exhaust system (e.g. chimney).
If the cooktop extractor is used in exhaust air mode, it draws
in air from the room in which it is installed as well as from
neighbouring rooms. If there is insufficient air supply, low
pressure will occur. Toxic gases could be drawn out of the
chimney or extraction ducting and back into the room.
Fig. 6.1 Exhaust air installation – not permitted
Fig. 6.2 Exhaust air installation – correct
XXIf simultaneously operating both a fireplace and the cooktop
extractor in the same room, ensure that:
XO the maximum low pressure is 4Pa (4 x 10–5bar);
XO a safety device (e.g. window contact switch, low pressure
warning device) is used to ensure that a sufficient supply
of fresh air is guaranteed;
XO the exhaust air is not be ducted into a chimney that is
used for exhaust gases of devices operated with gas or
other combustibles;
XO the installation is checked and approved by an authorised
certified engineer (e.g. heating engineer).
i If the cooktop extractor is used exclusively in
recirculation mode, operation with an open fireplace is
possible without any additional safety measures.
XXObserve all safety and warning information (see the “Safety”
chapter).
XXFollow the enclosed manufacturer‘s information
6.1 General installation instructions
i The power supply cable must be provided by the
customer.
i The appliance must not be installed above cooling
devices, dishwashers, stoves, ovens, washing machines
or dryers.
i The contact surface of the worktops and wall sealing
strips must be made of a heat-resistant material (up to
approx. 100 °C).
i Worktop cut-outs must be moisture-sealed using suitable
means and, where necessary, fitted with a thermal
insulator.
i The integrated cooktop extractor must not be used with
other cooktops.
General installation instructions for cooktops
i To ensure that the cooktops perform optimally at all
times, there must be sufficient ventilation beneath the
cooktops.
i The performance of the cooktops is affected or the
cooktops overheat if the warm air beneath the cooktops
cannot escape.
i If a cooktop overheats, the power is automatically
reduced or the cooktop is switched off completely (see
“Overheating protection”).
i If cable protection (false floor) is planned beneath the
appliance, this must be fitted so it does not obstruct
ventilation.
XXMake sure that the area below the cooktop has a sufficient air
supply.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora Pura at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora Pura in the language / languages: English as an attachment in your email.

The manual is 12,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora Pura

Bora Pura User Manual - German - 60 pages

Bora Pura User Manual - Dutch - 64 pages

Bora Pura User Manual - French - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info