711232
17
Zoom out
Zoom in
Previous page
1/44
Next page
EN
17
Installation
www.bora.com
6.4 Cut-out dimensions
INFO All dimensions from the front edge of the front
cover.
Worktop overhang
≥60 14x
(
≥74
)
Fig. 6.2 Worktop overhang
Please note the worktop overhang x when creating
the worktop cut-out. Applies to flush installation and
surface mounting.
INFO For cooktop extractor PKA used in conjunction
with straight ducting piece PKA1FEV, flush
mounting is also possible for worktop depths
≥ 650 mm.
6.4.1 Flush installation
x
A ±2
B ±2
544 ±2
≤ R5
≤ R5
≥ 74
(≥ 74)
516 ±2
≥ 700
Fig. 6.3 Cut-out dimensions ush installation
7 +0,5
14
10 - 40
Fig. 6.4 Groove dimensions for ush installation
6.3 Assembly instructions
6.3.1 Safety clearances
1
3
2
Fig. 6.1 Recommended minimum clearances
Maintain the following safety clearances:
[1] Rear minimum clearance of 50 mm between the worktop
cut-out and the rear corner of the worktop.
[2] Minimum clearance of 300 mm from the left and right of the
worktop cut-out to the adjacent cabinet or wall.
[3] Minimum clearance of 600 mm between the worktop and
the wall unit.
6.3.2 Worktop and kitchen units
Create the worktop cut-out taking into account the
specified cut-out dimensions.
Make sure that the cutting surfaces of the worktops
are properly sealed.
Comply with the instructions of the worktop
manufacturer.
Cross bars on the kitchen unit in the area of the
worktop cut-out may need to be removed.
No false floor is necessary below the cooktop. If cable
protection (false floor) is planned, the following must
be taken into account:
It must be fitted in such a way that it can be
removed for maintenance work.
To ensure sufficient cooktop ventilation, a minimum
distance of 15 mm to the bottom edge of the
cooktop is to be observed.
The drawers and/or shelves in the floor unit must be
removable.
A return flow aperture > 500 cm
2
is required in the
kitchen units for recirculation appliances (e.g. by
shortening the plinth boards or using suitable slatted
plinths).
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora Pro - PKA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora Pro - PKA in the language / languages: English as an attachment in your email.

The manual is 8,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora Pro - PKA

Bora Pro - PKA Additional guide - English, German - 2 pages

Bora Pro - PKA User Manual - German - 44 pages

Bora Pro - PKA Additional guide - Dutch - 2 pages

Bora Pro - PKA User Manual - Dutch - 48 pages

Bora Pro - PKA Additional guide - French - 2 pages

Bora Pro - PKA User Manual - French - 48 pages

Bora Pro - PKA Additional guide - Italian, Spanish - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info