674417
18
Zoom out
Zoom in
Previous page
1/120
Next page
18
en
Make sure that the unit is turned off.
Remove the top cover of the unit (Note: formation of
condensation may occur after use on the inside of the
cover) and take the water tank from the unit by using
the tank handle (9).
Turn the water tank upside down, unscrew the cap and
fill with water (9 – 10).
Close the tank cap securely, place the tank into the unit
and put the cover back on (11).
SLEEP-Mode
By pressing button B, the AUTO-Mode can be changed to
SLEEP-Mode (symbol K) and vise versa. In the SLEEP-Mode,
the desired relative humidity (rH) is preset to 45%. The unit
chooses the appropriate output level Low “L / Medium “M”
(symbol G), in order to attain the value of 45% rH as energy-
efficiently as possible.
In SLEEP-Mode, the rH can be changed at any time by using
button C; see C) Setting humidity level. If the output level
is changed by using button D, the SLEEP-Mode turns off
and the unit is operated manually; see D) Manual operation.
By pressing button B two times, the SLEEP-Mode can be
reactivated.
C) Setting humidity level
The appliance is fitted with a hygrostat. This measures the
relative humidity and switches the appliance off automati-
cally when the desired value is reached. The internal ven-
tilation remains turned on, to ensure an accurate reading of
the relative humidity. If the relative humidity falls below the
desired value, humidification resumes automatically. The
desired relative humidity can be adjusted in steps of 5% by
pressing button B. While selecting the desired humidity out-
put, the value display is blinking. The word DESIRED appears
on the display (symbol H). After a few seconds, the display
automatically changes to show the current value (symbol
H). Upon reaching the desired relative humidity, the display
shows DESIRED and CURRENT.
A relative humidity of between 40 and 60% is recom-
mended. The setting for the relative humidity ranges from a
minimum of 30% to a maximum of 70% relative humidity or
“CO” continuous mode.
Symbol E2
When the display shows “E2”, the current relative humid-
ity has reached 90%. For safety reasons, the appliance
switches off automatically. The appliance switches back
on, when the relative humidity falls below 85%.
A) Switch on/off
Pressing button A switches the appliance either on or off.
Button A is also used to start the decalcification mode. See
the section about “Decalcification Mode” (18 – 25). After
the unit is switched on, it is in AUTO-Mode (symbol J).
B) AUTO- / SLEEP-Mode
AUTO-Mode:
After the unit is switched on, it is in AUTO-Mode (symbol J).
The desired relative humidity (rH) is preset to 50%. The unit
chooses the appropriate output level Low “L / Medium “M”
/ High “H” (symbol G), in order to attain the value of 50% rH
as quickly as possible.
In AUTO-Mode, the rH can be changed at any time by using
button C; see C) Setting humidity level. If the output level
is changed by using button D, the AUTO-Mode turns off
and the unit is operated manually; see D) Manual operation.
By pressing button B, the AUTO-Mode can be reactivated.
Operation S450
L
M
H
AUTO
CURRENT
DESIRED
I
J K
L
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Boneco S450 Steamer at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Boneco S450 Steamer in the language / languages: All languages as an attachment in your email.

The manual is 2,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info