The most common cause of overheating is a clogged
lint filter and blocked vents.
Once the circuit breaker tripped, the appliance is not
heating. Proceed as follows:
- Switch off the appliance,
- wait about 10 minutes before you restart the op-
eration, and after correcting the cause.
- Press the reset switch to turn on the heating pow-
er again. You hear a clicking sound.
Delivery scope
Delivery scopeDelivery scope
Delivery scope
Vent hose
Installation
InstallationInstallation
Installation
WARNING:
WARNING:WARNING:
WARNING:
The appliance must not be connected to the mains
during installing. Otherwise there is da
dada
dan
nn
nger to life
ger to lifeger to life
ger to life or
electric shock hazard
electric shock hazardelectric shock hazard
electric shock hazard!
A
AA
Appliance location
ppliance locationppliance location
ppliance location
The site should be located near the water inlet
and outlet, as well as near a properly grounded
power socket.
Good ventilation around the appliance is required,
in order to dissipate the heat properly. Sufficient
clearance must be created for this purpose.
The clearance to the front must be created so,
that the appliance door can open without being
impeded.
Make sure that the floor on which the appliance is
installed, is even, heat-resistant and clean.
Take care of a solid and horizontal position of the
appliance. If the appliance is not horizontally lev-
eled, adjust the feet accordingly (see “Adjust the
feet”).
Avoid the installation:
Avoid the installation:Avoid the installation:
Avoid the installation:
- near heaters, next to a stove, direct sunlight or
any other heat sources;
- at locations with high humidity (e.g. outdoors),
as metal parts would be susceptible to corro-
sion under such circumstances;
- in rooms where the temperature drops below
5°C or above 35°C. Do not expose the appli-
ance any weather.
- near volatile or flammable materials (e.g. gas,
fuel, alcohol, paint, etc.).
Adjusting the feet
Adjusting the feetAdjusting the feet
Adjusting the feet
CAUTION:
CAUTION:CAUTION:
CAUTION:
The feet must never be removed. Do not restrict the
floor clearance through carpets, strips of wood or
similar. Danger of heat accumulation!
Danger of heat accumulation!Danger of heat accumulation!
Danger of heat accumulation!
Turn the feet to the right to let down the appli-
ance; turn to the left to lift it up. The feet must
have solid ground contact.
Check with a spirit level if the appliance is leveled
horizontally. If the appliance is not in balance, the
feet must be adjusted again.
Installation of the
Installation of the Installation of the
Installation of the vent
ventvent
vent
hose
hosehose
hose
The dryer has an air outlet on the back of the appli-
ance to vent the moist air.
NOTE:
NOTE:NOTE:
NOTE:
The distance between the dryer and the exhaust air
opening should be not too large in order to avoid an
accumulation of condensate in the tube.
Attach the accompanying vent hose at the air
outlet. Tighten the hose clockwise.
Lay the vent hose in the manner A or B.
Connect the vent hose to the exhaust opening (air
duct or window).
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bomann WT 5019 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bomann WT 5019 in the language / languages: English as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bomann WT 5019

Bomann WT 5019 User Manual - German - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info