SG968D/S-10M 4 Advanced Operations
Page 14
then the Time Lapse can’t be set to
Off
.
PIR Trigger
This parameter defines the sensitivity of the
PIR. There are four parameters: High, Normal,
Low and Off. The default value is “Normal”. The
higher degree indicates that the camera is more
easily triggered by motion, taking more pictures
or recording more videos. It is recommended to
use high sensitivity degree in a room or
environment with little interference, and to use
lower sensitivity for outdoor or environment with
lots of interference like hot wind, smoke, near
window etc. Furthermore, the sensitivity of the
PIR is strongly related to the temperature.
Higher temperature leads to lower sensitivity.
Therefore it is suggested to set a higher
sensitivity for high temperature environment.
Please note that if the time lapse is set to Off,
then the PIR trigger can’t be set to Off.
PIR Interval
This parameter means how long the PIR
sensor will be inactive after each triggering in ON
mode. During this time the PIR of the device will
not react to the motion of human (or animals).
The minimum interval is 0 second (meaning the
PIR works all the time). The maximum interval is
1 hour (meaning the PIR will be disabled for 1
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bolyguard SG968D-S-10M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bolyguard SG968D-S-10M in the language / languages: English as an attachment in your email.

The manual is 1,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info