2.7.1 Alarm input port specification
8 channels alarm input. Alarm input type unlimited.
The grounding and the com port of the alarm sensor are parallel (The alarm sensor is external power
supply) .
The grounding of the alarm and the DVR should be shared.
The NC port of the alarm sensor must be connected with the DVR alarm input port.
The grounding of the power supply and the alarm sensor must be shared when used in external power
supply.
2.7.2 Alarm output port specification
2 channels alarm output. There is external power supply when using the external alarm equipment.
Please refer to the relay relevant parameters to avoid the overload that damages main machine.
2.7.3 Alarm output port relay parameters
TypeJRC-27F
Interface material silver
rating
(resistance load)
Rating switch capacity 30VDC 2A, 125VAC 1A
maximal switch power 125VA 160W
maximal switch voltage 250VAC, 220VDC
maximal switch current 1A
isolation Homo-polarity interface 1000VAC 1minute
Inhomo-polarity
interface
1000VAC 1 minute
Interface and winding 1000VAC 1 minute
Surge voltage Homo-polarity interface 1500VAC (10×160us)
Turn-on time 3ms max
Turn-off time 3ms max
longevity mechanical
50×106 MIN3Hz)
electric 200×103 MIN (0.5Hz)
Environment
temperature
-40~+70
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for BML Safe CCTV 8CH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of BML Safe CCTV 8CH in the language / languages: English, German, Polish as an attachment in your email.

The manual is 14,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of BML Safe CCTV 8CH

BML Safe CCTV 8CH Additional guide - English - 33 pages

BML Safe CCTV 8CH Quick start guide - English, German, Polish - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info