The cooker hood must be installed centrally over a cooking appliance. The minimum
distance between the cooking surface and the metal grease filters on the underside of
the hood must be at least 650mm. To install the hood proceed as follows: -
1 - Firstly, draw a vertical line approximately 950mm up the wall from the centre of the cooking
appliance. Secondly, draw two vertical lines 90mm either side of the first line up to the
ceiling. Thirdly, draw four horizontal lines through the vertical lines at Y-J-X2-X1 as
illustrated in fig. 1 to give you your drilling positions.
2 - Drill eight 8mm diameter holes at X1-X2-J-Y and insert the plastic rawl plugs supplied as
illustrated in fig. 2 ensuring the brackets are fitted as shown in the blow up.
3 - Secure the two brackets C to the wall inserting two of the screws supplied through the
two holes on line X1-X2 as illustrated in fig. 2.
4 - Secure the locking washer D to the wall inserting one of the screws supplied through
hole Y as illustrated in fig. 2 ensuring the washer is fitted with the recess to the wall
as shown in the blow up.
5 - Slide the canopy down the wall to locate the key hole over the washer then secure the
canopy to the wall by inserting two of the screws supplied through the two outer holes in
the rim of the canopy J1 and J2 as illustrated in fig. 3.
To prevent the canopy from accidentally being dislodged from the wall at anytime
fit the final screw supplied through hole J3.
6 - Fit the ducting flange E over the rectangular air outlet in the top of the canopy rim using
the two 2.9mm self tapping screws provided as illustrated in fig. 4.
7- EXTRACTION OR RECIRCULATION INSTALLATION:
7A EXTRACTION (Ducted)
- When used in the extraction(ducted) mode contaminated air enters the cooker hood
through the metal grease filters and passes out through ducting to the outside.
- When the hood is ducted to the outside the 150 to 120mm diameter ducting spigot G
must be fitted onto the ducting flange E as illustrated in fig. 5.
- The (optional) ducting required must be 120mm in diameter and made from fire retardent
material. Where flexible ducting is fitted it should not be turned through very tight bends
as this could impair the performance of the hood.
- IMPORTANT: The ducting used inside the chimney must not be larger than 120mm
in diameter as this could subsequently prevent the chimney fitting correctly.
- The ducting system for this appliance must not be connected to any ventilation
system which is being used for any other purpose.
7B RECIRCULATION (Filtered)
- When used in the recirculation mode (filtered) contaminated air enters the cooker hoDD
through the metal grease filters, passes through the (optional) cleansing charcoal filters
where it is purified and passes out into the kitchen through the grilles in the chimney.
- When the hood is fitted in the recirculation mode the air deflector H should be fitted as
illustrated in fig. 6.
- Fit the (optional) charcoal filters by repeating the following operation on each side of the
motor housing. Place the two key hole slots in the filter L over the tabs on the motor
housing M and turn the filter clockwise to lock the filter in position as illustrated in fig. 7.
INSTALLATION
2
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Blomberg dkp 2010 x at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Blomberg dkp 2010 x in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info