586374
9
Zoom out
Zoom in
Previous page
1/60
Next page
9
ENGLISH
Double insulation
This tool is double insulated; therefore no
earth wire is required. Always check that
the power supply corresponds to the
voltage on the rating plate.
Guard against electric shock.
Electric safety can be further improved by using
a high-sensitivity (30 mA / 30 mS) residual
current device (RCD).
Your appliance is designed for use on AC
(mains) electrical supplies only. Do not attempt
to use it on any other supply.
Plug replacement (UK only)
Mains plug replacement (U.K. & Ireland only)
If a new mains plug needs to be fitted:
Safely dispose of the old plug.
Connect the brown lead to the live terminal in
the new plug.
Connect the blue lead to the neutral terminal.
Connect the green/yellow lead to the earth
terminal.
Warning! Follow the fitting instructions supplied with
good quality plugs. Recommended fuse: 13 A.
Extension cables
When using the appliance outdoors, only use
extension cables intended for outdoor use.
Up to 25 m of Black & Decker 1.5 mm
HO5VVF 3-core extension cable can be used
without loss of power.
Assembly prior to use (Fig. B & C)
Vacuum tube assembly (Fig. B)
B
Vacuum tubes must be assembled
together before use.
To ease assembly apply soapy water
solution to joint area.
Align the notches (15) and the triangles
(14) on upper (4) and lower (5) tubes.
Push the lower tube (5) firmly into the
upper tube (4), until the triangles click
into place. (Never operate apart).
In the interests of safety, it is not
intended for the tubes to be separated
once assembled.
Blow tube assembly (Fig. C)
C
Blow tube must be assembled to the
blow clamshell before use.
Align the circles (16) on the clamshell
(6) and the tube (7).
Push the tube (7) firmly onto the
clamshell (6) until the circles click into
place.
For storage the blow tube can be
detached from the blow clamshell by
depressing the circles on either side
and gently sliding off the tube.
Carrying strap assembly (Fig. D - G)
Fit the carrying strap to the powerhead,
if required, and adjust to suit the user.
For your comfort, the shoulder strap is
designed to be fitted in two ways:
Single Point Attachment (Fig. D)
Clip the hook (17) through the eyelet
(18) on the powerhead.
Adjust the length of the loop with the
buckle.
Double point attachment
(Fig. D, E, F & G)
Clip the hook (17) through the eyelet
(18) on the powerhead.
Remove the loose end of the strap from
the buckle.
Pass the loose (19) end under the boss
(20), and thread it back through the
buckle (21).
Adjust the length of the loop with the
buckle (Fig. G).
On/off switch (Fig. H1, H2, H3)
Warning! Use both hands to grip the
product firmly when switching on.
For extra control, your blowvac is fitted
with a two speed switch located on the
handle of the powerhead.
The switch has a central off. Position 0
(Fig. H1).
To use in low speed, move the switch
fully to the rear. Position I (Fig. H2).
To change to high speed push the
switch back to the off position and then
fully forward. Position II (Fig. H3).
Cable restraint (Fig. I)
I
A cable restraint is incorporated into the
rear of the powerhead.
Loop the cable (22) through the cable
restraint (12).
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Black Decker GW350 T3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Black Decker GW350 T3 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 0,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Black Decker GW350 T3

Black Decker GW350 T3 User Manual - Danish, Swedish, Norwegian, Finnish - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info