12
8.4.4 Changing Engine Oil
- changing engine oil refers to the content in
8.4.3 and 8.4.1.
8.5 Oil shortage cut-out
This generator has a Low Oil level Protection
system.
The oil shortage cut-out responds if there is
too little oil in the engine. In this case it will
not be possible to start the engine or it will
cut out automatically after a short period
of time. It cannot be started again until the
engine oil has been topped up (see point
8.4.1).
8.6 Storage
If the generator is going to stop used for long
time (more than 3 months).
Make sure have done following points:
- Make sure the fuel tank is empty.
The fuel tank of the generator is not fully
sealed. Long time fuel storage could cause
fuel deteriorate.
- Make sure there is no fuel in the carburetor.
To empty the carburetor. Unscrew the
carburetor out let screw. Collect the fuel
inside. Then screw it back on. (B15)
Fuel residual could cause carburetor
jamming.
- Make sure the engine is oil empty.
Emptying the oil refers to the content in 8.4.3.
Long time oil storage could cause oil
deteriorate. Deteriorated oil could jam the oil
sensor.
Important!
Never storage the generator exposed out
door.
9. Transport
ATTENTION!
Slipping or falling unit can crush hands and
feet.
- Carry the generator on transportation
handles:
- Lift the generator evenly.
- Carry the generator to the operating place.
- Drop the generator evenly.