captured by the lter system.
IMPORTANT NOTES:
Your ioniser may produce an occasional popping or
cracking sound. This is normal and occurs when a
small buildup of ions is discharged.
After extended use, you may notice dust around the
grilles or front panel.
This is caused by negative ions exiting the air
outlet, evidence of the ionisers air cleaning
effectiveness.
You can remove the dust with a soft brush
or clean, damp cloth. Larger particles may
be attracted to positively charged surfaces
throughout the home, like walls or oors.
This may occur more frequently when the lter
is nearing the end of its useful product life and
unable to capture as many charged particles.
Excessive amounts of pet dander, dust, or
smoke may decrease the life expectancy of the
lters and interfere with the ionisation process.
To help prevent particles from attracting to surfaces
throughout your home:
You may want to run the ioniser function less
often.
Check the condition of the lters more
frequently.
Always clean the lters at the recommended
intervals (See CLEANING THE FILTERS).
Using the ioniser with dirty lters may result
in dirty particles exiting the air purier and
attracting to walls, carpets, furniture, or other
household objects. These dirty particles may
prove difcult to remove.
CAUTION: The levels of ozone produced by the
ioniser in this appliance fall within the recommended
safe limits. However, in high concentrations, ozone
can be harmful to birds and small pets. To prevent
ozone buildup when using the ioniser mode, operate
the appliance in a well ventillated area.
HEPA-TYPE FILTER
HEPA-type (High Efciency Particulate Air) lters
are designed to remove up to 99% of airborne
pollutants, at 2 microns or larger, from the air that
passes through them. These include tobacco smoke,
household dust, pet dander and pollen.
UV LIGHT
Ultraviolet light is a proven technology used to
destroy various types of bacteria, viruses, fungi and
mould spores and is commonly used in hospitals and
commercial settings. This air purier uses a UV-C
bulb.
PHOTOCATALYTIC OXIDATION
Photocatalyic oxidation (PCO) is achieved when
you combine UV light with a Titanium Dioxide (TiO2)
coating. PCO removes Volatile Organic Compounds
(VOCs) and odours which include harmful pollutants
such as formaldehyde, ammonia, toxic fumes and
chemicals such as paint and many other common
contaminates released by building materials and
household cleaners.
PRE-OPERATING INSTRUCTIONS
Carefully unpack your air purier.
Select a rm, level surface with no obstructions
to the air inlets or outlets.
OPERATING INSTRUCTIONS
DO NOT POINT FILTERED AIR OUTLET
TOWARDS WALL. DO NOT USE THE IONISER
FOR LONG PERIODS OF TIME AS THIS CAN
CAUSE BLACKENING OF WALLS IF THE FILTERS
ARE NOT CLEANED REGULARLY.
To operate your air purier:
1. Press the on/off button
F
. Your air purier will
turn on at the maximum fan speed (5).
2. Select the desired fan speed (5, 4, 3, 2 or 1)
by pressing the fan speed select button
E
. The
display will show the selected speed.
Ioniser/UV mode
The ioniser and UV features can be selected
individually or both together. They will operate at any
selected fan speed.
1. Press the UV/Ionic mode selector button
D
to
select UV and ioniser, UV only, ioniser only or
none. The display will show the selected mode.
Note that the illuminated strip
M
will light up
when the UV feature is selected.
Timer Mode
You can set the timer so that your air purier
automatically turns off when the desired time has
elapsed:
1. Press the timer select button
C
until you reach
the desired number of hours you want the unit
to operate (1, 2, 3, 4, 5, 6, 7 or 8 hours).
2. The number of hours selected and the timer
active icon
J
will be shown on the display.
3. When the time has elapsed, your air purier will
turn off.
To cancel the timer, press the timer select button
C
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bionaire IAP001X at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bionaire IAP001X in the language / languages: All languages as an attachment in your email.

The manual is 1,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info