470353
17
Zoom out
Zoom in
Previous page
1/80
Next page
17
Repeat the measurement if the flashing icon
is displayed
after the measurement. Please note that you should rest for 5
minutes between measurements and not talk or move during
the measurement. If the icon
appears often, please contact
your doctor. Any self-diagnosis and treatment based on the
test results may be dangerous. It is vital to follow your doctor’s
instructions.
WHO classification:
The World Health Organization (WHO) and National High Blood
Pressure Education Program Coordinating Committee have de-
veloped a blood pressure standard, according to which areas of
low- and high-risk blood pressure are identified. This standard,
however, is a general guideline as individual’s blood pressure
varies among different people and different age groups ... etc.
It is important that you consult with your physician regularly.
Your physician will tell you your normal blood pressure range
as well as the point at which you will be considered at risk.
Table for classification of blood pressure values (unit of measurement mmHg) for adults:
Range Systolic Diastolic Action
Hypotonia (degraded blood pressure) lower than 105 lower than 60 Check with doctor
Normal range between 105 and 120 between 60 and 80 Self check
Pre-hypertensive blood pressure range*
between 120 and 140 between 80 and 90 Check with doctor
High blood pressure - degree
between 140 and 160 between 90 and 100 Consult your doctor
High blood pressure - degree
higher than 160 higher than 100
Consult your doctor
(*) Blood pressure range that might transfer to high blood pressure Adapted from JNC 2003
The WHO classification in the display shows the range of the
measured blood pressure.
If the values for systolic and diastolic pressure are in two dif-
ferent WHO ranges (e.g. systolic in the grade
hypertension
range and diastolic pressure in the normal range), the WHO
classification on the unit always indicates the higher range
(grade
hypertension in the example described).
5.6 Resting indicator measurement (using HSD diagnostics)
The most frequent error made when measuring blood pressure
is taking the measurement when not at rest (haemodynamic
stability), which means that both the systolic and the diastolic
blood pressures are incorrect in this case. During blood pres-
sure measurement, the device automatically determines wheth-
er the circulatory system is sufficiently at rest or not.
If there is no indication that the circulatory system is not suf-
ficiently at rest,
(haemodynamic stability) is displayed and
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer BM 70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer BM 70 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer BM 70

Beurer BM 70 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info