: lack of haemodynamic stability
It is very probable that the measurement of systolic and di-
astolic blood pressure has not been carried out at rest and has
therefore distorted the measurement.
Repeat the measurement after a rest and relaxation period of at
least 5 minutes. Go to a sufficiently calm and comfortable spot
and remain there calmly; close your eyes, breathe deeply and
evenly and try to relax.
If the following measurement shows a lack of stability again,
repeat the measurement after another period of rest. In case of
further unstable measurements, identify these measurements
as they were taken when the circulatory system had not be suf-
ficiently rested.
In this case, inner unrest of the nervous system could be the
cause, which cannot be cured by brief periods of rest. Develop-
ing cardiac arrhythmia can also prevent stable blood pressure
measurements.
A lack of resting blood pressure can have various causes, such
as physical or mental strain or distraction and speaking or
experiencing heart rhythmic disturbance during the measure-
ment.
In an overwhelming number of cases, the HSD diagnosis will
give a very good guide as to whether the circulatory system is
rested when taking the measurement. Certain patients suffer-
ing from cardiac arrhythmia or chronic mental conditions can
remain haemodynamically unstable in the long-term, some-
thing which persists even after repeated periods of rest. The
precision of the results of the resting blood pressure is reduced
in these users. Like any medical measurement method, the
precision of the HSD diagnosis is limited and can lead to incor-
rect results in some cases. The blood pressure measurements
taken when the circulatory system was at rest represent par-
ticularly reliable results.
8. Calling up stored values
You can call up values from the 2 user memories and display
the averages.
Press the M1 or M2 memory buttons. Firstly, the average of
all values stored in this user memory will be displayed. This
is denoted by the letter “A” in the display.
If you press the memory buttons again, further individu-
al measurements appear with WHO, cardiac arrythmia and
HSD. These individual values are numbered from 1 to 60. The
time and date are alternately displayed after 2.5 seconds.
If there are 60 individual values in the memory at the same
time, the oldest value is deleted in order to make room for
the new value.
Use the start/stop button to turn off the device, or it will
turn off automatically after approx. 30 seconds.
Tip: You can also use the 2 user memories to separately store
measurements – e.g. mornings and evenings.
Deleting stored values
To delete an entire user memory, you have to select the rele-
vant user memory. The average is displayed and denoted with
the letter “A. Press and hold memory button M1 or M2 until the
display flashes and keep pressing the button until the display
completely switches off.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer BM 60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer BM 60 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer BM 60

Beurer BM 60 User Manual - Dutch, Danish, Portuguese, Swedish, Norwegian - 104 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info