On no account must you immerse the computer in water,
otherwise liquid can enter it and cause demage.
When storing the device, make sure that no heavy objects
are placed on top of it. Remove the batteries. The cuff tube
should not have any sharp kinks.
8. Error messages / troubleshooting
In case of faults, the message appears in the display.
Error messages can occur when
1
. inflation pressure is higher than 300 mmHg,
2
. blood pressure is unusually high or low,
3
. you move or talk during the measurement (in addition to
, the cardiac arrhythmia icon appears in the
display),
4
. the cuff tube is not inserted properly,
5
. the cuff is inflated for longer than 16 seconds.
In the above cases, you must repeat the measurement. Make
sure that the cuff tube is properly inserted and that you do
not move or talk. Re-insert the batteries if necessary, or else
replace them.
9. Specifications
Model No. BM 19
Method of Measurement Oscillometric, non-invasive blood
pressure measurement on the upper
arm
Range of Measurement Pressure 0 – 300 mmHg,
systolic 40 – 280 mmHg,
diastolic 40 – 280 mmHg,
pulse 40 –199 beats/minute
Accuracy of the systolic ± 3 mmHg /
pressure reading diastolic ± 3 mmHg /
pulse ± 5 % of the displayed value
Measuring uncertainty max. permissible standard deviation
according to clinical testing:
systolic: 8 mmHg /diastolic: 8 mmHg
Sets of Memory 2 x 60 memory places
Unit Dimension L147 x W104 x H66 mm
Unit Weight Approx. 310 g
Cuff Size cuff for upper arm circumference of
23 cm – 33 cm
Operating Temperature + 10 °C to + 40 °C, ≤ 85 % RH
Storage-and - 20 °C to + 70 °C, ≤ 85 % RH
transportemperature
Power Supply 4 x 1,5 V AA batteries (alkaline type
LR6)
Battery Life For approx. 250 measurements,
depending on blood pressure level
or inflation pressure
Accessories With storage pouch, instruction
manu al, 4 pcs “AA” battery
Classification Application part Type BF
Protection class internal power supply, IPX0,
no AP or APG, continuous operation
Key to symbols Important! Read the operating
instruction!
Application part Type BF
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer BM 19 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer BM 19 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 3,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info