470662
53
Zoom out
Zoom in
Previous page
1/56
Next page
Beurer BGL60 mg/dL 53
EMC
This unit complies with European standards EN 61326 and EN 60601-1-2 and is
subject to special precautions regarding electromagnetic compatibility. Note that
portable and mobile RF communication equipment can affect this unit. Further
details can be requested by contacting the customer service address provided
below.
Note regarding function of test strips
The test strips enable a quantitative measurement of the glucose content of capil-
lary whole blood. When the slit for collecting blood comes into contact with a drop
of blood, it fills automatically through simple capillary action. The blood is sucked
into the absorbing slit of the test strip and the measuring device measures the
sugar level of the blood.
The test is based on the measurement of an electric current caused by a chemi-
cal reaction between the glucose and the test strip reagent. The measuring de-
vice analyses this current. The flow of current depends on the glucose content of
the blood sample. The results are shown in the display of the measuring device.
Only a small quantity of blood is required (0.5 microlitres) and the measurement
takes approx. six seconds. The strips can detect blood sugar levels in the range
20 to 600 mg/dL.
Chemical components of the test strip sensor
Glucose oxidase 10%
Electron shuttle 50%
Enzyme protection 8%
Non-reactive components 32%
Note regarding function of the control solution
The control solution contains a fixed concentration of glucose that reacts with the
test strip. A test with the control solution is performed in the same way as a blood
test, but the control solution is used instead of blood. The measurement result
from the control solution must lie within the results range. This results range is
printed on every test strip container.
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer BGL 60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer BGL 60 in the language / languages: English as an attachment in your email.

The manual is 2,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info