470662
28
Zoom out
Zoom in
Previous page
1/56
Next page
28 Beurer BGL60 mg/dL
5.4 Evaluating a blood pressure measured value
Your measuring device can process measured values between 50-270 mmHg
(systolic), 20-200 mmHg (diastolic) and 40-199 beats/min.
Blood pressure, WHO classification:
The World Health Organization (WHO) and the National High Blood Pressure
Education Program Coordinating Committee have developed standard blood
pressure values for detecting blood pressure levels with high and low risk. How-
ever, these standard values serve only as general guidelines, since the individual
blood pressure of different people and different age groups etc. deviates.
It is important that you consult your physician at regular intervals. Your physician
will provide you with your individual values for normal blood pressure and the
value above which the blood pressure level should be regarded as dangerous.
Classification of blood pressure levels for adults (measuring unit: mmHg)
Range of the blood pressure
levels
Systolic
pressure
Diastolic
pressure
Remedy
Level 3: severe hypertension
180 110 Visit a physician
Level 2: moderate hypertension
160-179 100-109 Visit a physician
Level 1: mild hypertension
140-159 90-99 Regular check-up by your
physician
High normal
130-139 85-89 Regular check-up by your
physician
Normal
120-129 80-84 Self-check
Optimal
< 120 < 80 Self-check
Source: WHO, 1999
The WHO classification in the display shows the range in which the measured
blood pressure belongs. If the systolic and diastolic values are in two different
WHO ranges (e.g. systolic pressure in the hypertension range level I and diastolic
pressure in the normal range), then the WHO classification on the unit always
shows you the higher range, in the example given, "Hypertension level I".
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer BGL 60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer BGL 60 in the language / languages: English as an attachment in your email.

The manual is 2,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info