Permissible operating
conditions
+10 °C to +40 °C, ≤85 % relative
humidity (non-condensing)
Permissible storage
conditions
-20 °C to +50 °C, ≤85 % relative
humidity, 700-1050 hPa ambient
pressure
Power supply 2 x 1.5V
AAA batteries
Battery life For approx. 200 measurements,
depending on levels of blood pres
-
sure and pump pressure
Accessories Instructions for use, 2 x 1.5V AAA
batteries, storage box
Classification Internal supply, IPX0, no AP or
APG, continuous operation, appli
-
cation part type BF
This device is in line with European Standard EN
60601-1-2 and is subject to particular precautions with
regard to electromagnetic compatibility (EMC). Please
note that portable and mobile HF communication sys-
tems may interfere with this unit. More details can be
requested from the stated Customer Services address
or found at the end of the instructions for use.
This device corresponds to the EU Medical Devices
Directive 93/42/EEC, the German Medical Devices Act
(Medizinproduktgesetz) and the standards EN1060-1
(non-invasive sphygmomanometers, Part 1: General
requirements), EN 1060-3 (non-invasive sphygmoma-
Subject to errors and changes
nometers, Part3: Supplementary requirements for
electro-mechanical blood pressure measuring systems)
and IEC 80601-2-30 (Medical electrical equipment –
Part 2-30: Particular requirements for the basic safety
and essential performance of automated non-invasive
sphygmomanometers).
The accuracy of this blood pressure monitor has been
carefully checked and developed with regard to a long
useful life.
If using the device for commercial medical purposes,
it must be regularly tested for accuracy by appropriate
means. Precise instructions for checking accuracy may
be requested from the service address.
We hereby guarantee that this product complies with
the European R&TTE Directive 1999/5/EC.
Please contact the specified service address to obtain
further information, such as the CE Declaration of Con-
formity.
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer BC 57 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer BC 57 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 9,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer BC 57

Beurer BC 57 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info