Manufacturer
Storage
RH ≤95%
-20°C
55°C
Permissible storage temperature and
humidity
Operating
5°C
40°C
RH ≤90%
Permissible operating temperature and
humidity
Keep dry
SN Serial number
0483
The CE labelling certifies that the prod-
uct complies with the essential require-
ments of Directive 93/42/EEC on medi-
cal products.
Advice on use
In order to ensure comparable values, always measure
your blood pressure at the same time of day.
Before every measurement, relax for about five minutes.
If you want to perform several measurements on the
same person, wait five minutes between each meas-
urement.
Do not take a measurement within 30 minutes after
eating, drinking, smoking or exercising.
Repeat the measurement if you are unsure of the
measured value.
The measurements taken by you are for your infor-
mation only – they are not a substitute for a medi-
cal examination! Discuss the measurements with your
doctor, and never base any medical decisions on them
(e.g. medicines and their administration)!
Do not use the blood pressure monitor on newborns,
pregnant women or patients with preeclampsia.
In the case of restricted circulation on the arm as a
result of chronic or acute vascular diseases (including
vascular constriction), the accuracy of the wrist meas-
urement is limited. In this case you should avoid using
an upper arm blood pressure monitor.
Cardiovascular diseases may lead to incorrect meas-
urements or have a detrimental effect on measurement
accuracy. The same also applies to very low blood
pressure, diabetes, circulatory disorders and arrhyth-
mias as well as chills or shaking.
The blood pressure monitor must not be used in con-
nection with a high-frequency surgical unit.
Only use the unit on people who have the specified
wrist measurement for the device.
Please note that when inflating, the functions of the
limb in question may be impaired.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer BC 31 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer BC 31 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 1,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer BC 31

Beurer BC 31 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info