7
BEFOREINSTALLATION
This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance must be installed in accordan ce
withthenorms&standardsofthecountrywhere
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the absence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuelGasCodeANSIZ223.1–
latestedition**orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codes or, in the absence oflocal codes, with the
National
ElectricalCode,ANSI/NFPA70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to
the gas supply line. Do not bend or damage the
flexibleconnectorwhenmovingthe
appliance.
This appliance must be used with the pressure
regulator provided. The regulator shall be
properlyinstalledinorderto beaccessible when
theapplianceisinstalledinits final location.The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressureregulatorhas½”
female
pipe thread. The appropriate fitting must be
determined based on the sizeofyour gas supply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduringanypressuretesting
ofthegas
supplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
All opening and holes inthe wall and floor, back
and under the appliance shall be sealed before
installationoftheappliance.
Amanualvalve shallbeinstalledinan accessible
location in the gas
line external to the appliance
for the purpose of turningon or shutting off gas
totheappliance
WARNING!
Donotuseaerosolspraysinthevicinityofthis
appliancewhileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used with the appliance; in each case it
shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmayaffectother vented appliances; in
each case it shall be installed in conformity with
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with natural
gas. For use with propane lp gas
please follow the conversion procedure
described on pg. 17. A step by step conversion
procedureisalsoincludedwitheachsetoflpgas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
to the gas appliance pressure regulator is 20’’
water
column(5kPa).
The minimum gas supply pressure for checking
theregulatorsettingshallbeatleast1“w.c.(249
Pa)abovetheinletspecifiedmanifoldpressureto
the appliance (this operating pressure is 4” w.c.
(1.00kPa)forNaturalGas and11”w.c.(2.75kPa
forLPGas).