GASCONVERSION
WARNING!
Beforecarryingoutthisoperation,disconnect
theappliancefromgasandelectricity.
Gasconversionshallbeconductedbyafactory
trainedprofessional.
Callthecustomerservicehotlinetoidentifya
factorytrainedprofessionalnearyourhome.
The gas conversion procedure for this range
includes6steps:
1. Pressureregulator
2. Surfaceburn ers
3. Mainovenburner
4. Broilerburner
5. Visualcheckspriortoclosureofovenbottom
panel
6. Adjustmentofminimumsetting
The conversion is not completed if all 6 steps
havenotbeenconcludedproperly.
Beforeperformingthegasconversion,locatethe
package containing the replacement nozzle
shipped with every range. IMPORTANT: Each
nozzle has a number indicating its flow diameter
printedonthebody.Consultthetableonpage20
formatchingnozzlestoburners.
Save the nozzles removed from the range for
futureuse.
STEP1:PRESSUREREGULATOR
The pressure regulator supplied with the
applianceisaconvertibletypepressureregulator
for use with Natural Gas at a nominal outlet
pressureof 4” w.c. or LP gasat a nominal outlet
pressure of 11” w.c. and it is prearranged from
the factory to operate with one of these
gas/pressureas indicatedin the labels
affixed on
theappliance,packageandInstructionbooklet.
Toconverttheregulatorforusewithotherliquid
propaneLPgas:
1. Unscrew by hand the upper cap of the
regulator, remove the white plastic
attachment from the cap, reverse its
directionand screwitagainfirmlyagainstthe
cap.The
whiteplasticattachmenthasarrows
indicating the position for natural gas (NAT)
andLPgas(LP).
2. Screw by hand the metal cap in the original
positionontheregulator.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bertazzoni PRO244 GAS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bertazzoni PRO244 GAS in the language / languages: English as an attachment in your email.

The manual is 0,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info