612639
5
Zoom out
Zoom in
Previous page
1/24
Next page
- Remember that the earth wire must not be interrupted by the switch.
- Alternatively the electrical connection can also be protected by a differential switch of high sensitivity.
- You are strongly advised to fix the special yellow-green earth wire to an efficient earthing system
ATTENTION: The appliance conforms with the regulations of directives 90/396EEC (Gas Directive)
regarding gas appliances for domestic use and the like, 93/68 and 73/23 (Low Voltage Directive) regarding
electrical safety and 2004/108/CE, 93/68 and 89/336 (EMC Directive) regarding electromagnetic
compatibility.
Wiring diagrams Wiring diagram description
For hotplate see Fig. 13. 1. Cable terminal L. Black
2. Ignition switch N. White
3. Spark generator T. Green (earth)
4. Ignition spark
MAINTENANCE OF THE MACHINE
CHANGING THE PARTS
Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply.
To replace different components such as burners, taps and electrical parts you must take out the hob from
the kitchen unit by releasing the fixing hooks, unscrew the fixing screws of the burners on the work top,
unscrew the fixing nuts of the electric plates which are visible on the lower part of the hob and remove the
worktop in order to carry out the replacement of the defective parts.
NOTE: If the taps need replacing you also need to unscrew the two fixing screws of the gas ramp at the
bottom of the hob which are found on the upper part of the latter.
For appliances equipped with automatic “ON” switches you must dismantle the “ON” switch chain before
replacing the taps.
You are advised to change the seal on the tap every time you replace a tap in order to ensure a perfect hold
between the body and ramp.
WARNING: The electric cable which is provided with the appliance is connected to the appliance with a type
X connection and thus can be replaced with the same type of cable as that installed without using special
tools. In the event of wear or damage to the mains cable, replace it with :
Type/ section of mains cable H05VV-F 3x0,75 mm2 or H05RR-F 3x0,75 mm2
WARNING: If you replace the electric mains cable the installer must have the earth conductor about 2
cm longer than the phase conductors and must also take heed of the warnings regarding electric
connection.
Room ventilation Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE N°2: Adapting to different types of gas APPLIANCE CATEGORY: III
Burner
Pressure
Nozzle
Nominal Charge
Reduced Charge
Diameter
diameter
by-pass 1/100mm
mbar
1/100mm
g/h
l/h
Kw
kcal/h
kw
kcal/h
8
145
-
227
1,00
860
0,30
258
27 reg
Auxiliary
20
77
-
95
1,00
860
0,30
258
27 reg
28
50
73
-
1,00
860
0,30
258
27
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bertazzoni PM6030X PM6V A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bertazzoni PM6030X PM6V A in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info