605248
6
Zoom out
Zoom in
Previous page
1/32
Next page
Yellow/Green wire: connect to GND (ground)
A dedicated line and junction box should be used to connect the oven to a 20 A circuit.
ROOM VENTILATION LOCATION AND VENTING.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE A: Adapting to different types of gas
Burner
Gas
Pressure
Max Rate
Min Rate
By-pass size
Type
[mbar]
g/h
l/h
kw
kcal/h
kw
kcal/h
1/100mm
Town G110
8
-
397
1,75
1505
0,44
378
31 reg.
Semi-Rapid
Natural G20
20
-
167
1,75
1505
0,44
378
31 reg.
Butane G30
30
127
-
1,75
1505
0,44
378
31
Propane G31
37
125
-
1,75
1505
0,44
378
31
Town G110
8
-
681
3
2580
0,75
645
42 reg.
Rapid
Natural G20
20
-
286
3
2580
0,75
645
42 reg.
Butane G30
30
218
-
3
2580
0,75
645
42
Propane G31
37
214
-
3
2580
0,75
645
42
Town G110
8
-
181
0,8
688
0,3
258
27 reg.
Inner
Natural G20
20
-
76
0,8
688
0,3
258
27 reg.
Butane G30
30
58
-
0,8
688
0,3
258
27
Dual
Propane G31
37
57
-
0,8
688
0,3
258
27
Town G110
8
885
3,9
3354
1,8
1549
65 reg
burner
Outer
Natural G20
20
-
419
4.4
3784
1,8
1548
65 reg
Butane G30
30
298
-
4,1
3526
1,8
1548
65
Propane G31
37
293
-
4,1
3526
1,8
1548
65
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 11) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most
suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
DESCRIPTION
DESCRIPTIVE CAPTION FOR HOB (fig.9)
1. Dual burner
2 Rapid burner
3. Rear Induction element
4. Front induction element
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bertazzoni PM361I0X at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bertazzoni PM361I0X in the language / languages: English, Dutch as an attachment in your email.

The manual is 1,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info