605227
5
Zoom out
Zoom in
Previous page
1/40
Next page
5
considered when undertaking any installation. Failure to install the appliance
correctly will render the warranty null and void.
Range cookers are heavy and should be handled by two people. Never lift or drag a
range by the oven handles as damage may occur.
Note: Pictures and graphics in this manual cover different models and may vary in
minor details from your cooker.
INSTALLING RANGE COOKER
Rating of Services The rating plate is visible in the storage area of the cooker and a copy is also
attached to page two of the user manual.
Before connecting the cooker, check that the requirements on the rating plate
correspond with those of the electrical system and gas supply (where applicable).
Ensure that the electrical system and isolating switches have a suitable capacity to
carry the maximum power as indicated on the rating plate.This chart can be used as
a guide to the electrical supply ratings.
Table N°1
Cooker model Type
MCB size for dedicated
cooker circuit
The cable of
alimentation
60 cm single oven Gas hob top 13 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
*60 cm single oven Induction hob top 32 AMP MCB
H07RN-F 3X4
mm²
60 cm single gas oven Gas hob top 13 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
90 cm single hybrid oven Gas hob top 16 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
90 cm single gas oven Gas hob top 13 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
90 cm single oven Gas hob top 16 AMP MCB
H05RR-F or H05VV-F
3X1,5
mm²
*90 cm single oven Induction hob top 32 AMP MCB
H07RN-F 3X4
mm²
90 cm twin oven Gas hob top 20 AMP MCB
H05BB-F or H05SS-F
3X2,5
mm²
*90 cm twin oven Induction hob top 32 AMP MCB
H07RN-F 3X4
mm²
100 cm twin oven Gas hob top 20 AMP MCB
H05BB-F or H05SS-F
3X2,5
mm²
*100 cm twin oven Induction hob top 32 AMP MCB
H07RN-F 3X4
mm²
100 cm XG (3 oven compartments) Gas hob top 32 AMP MCB
H07RN-F 3X4
mm²
*100 cm XG (3 oven compartments) Induction hob top 40 AMP MCB
H07RN-F 3X6
mm²
120cm twin oven Gas hob top + griddle 32 AMP MCB
H07RN-F 3X4
mm²
* With diversity factor applied
Positioning The cooker may be installed in a kitchen or open-plan kitchen diner but not in a
room containing a bath or shower. The cooker should be positioned in an area with
good light and free from draughts.
Any shelf or unit of combustible material should be at least 660mm above the
hotplate. In addition an area of 75mm wide on either side and behind the hotplate
must be clear of any combustible materials to a height of 400mm. Units must not
overhang over the hob.
Kitchen cabinets may be fitted flush to the sides of the cooker, but to allow for
cleaning and servicing
It is recommended that a 2.5mm gap be allowed on each side so that the cooker
may be moved if necessary.
The worktop or kitchen cabinets must not protrude beyond the height of the cooker
hotplate frame.
Ventilation Your appliance is not connected to a combustion products evacuation device. Th
e room in which it is to be installed must have an air supply in accordance with
national standards. The room must have an opening window or equivalent, and
some rooms may require a permanent vent in addition to the opening window.
General guidelines: The cooker must not be installed in a bedsit room of 20m³
or
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bertazzoni HER90 6 MFE DNET at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bertazzoni HER90 6 MFE DNET in the language / languages: English as an attachment in your email.

The manual is 1,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bertazzoni HER90 6 MFE DNET

Bertazzoni HER90 6 MFE DNET Usermanual and installation guide - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info