Installation
6005738_a – 07.06.2022
3.5.4 Hanging the device in place
The device is designed to be hung on walls. The chimney can
be adapted to the ceiling height by pulling it out.
When mounting on a solid wall:
Make sure that the wall has sufficient load bearing
capacity.
Use the fastening materials provided.
With different installation situations:
Enquire about alternative fastening systems (e.g. consult
with your architect).
Only use fastening hardware suitable for the type of wall.
x
478
30
270
508
30
290
==
600
Safety distance (x):
yRecommendation 650 mm.
yWith electric hobs, at least 600 mm.
yWith gas hobs, at least 650 mm.
Observe the specifications for the cooking appliances
(e.g. installation above a solid fuel stove).
Determine the hanging position.
Ensure that the chimney mount is correctly positioned:
yThe chimney cannot be mounted if it falls below the
required measurement (30 mm).
yAny irregularities (e. g. in the ceiling) can be
compensated with slotted holes.
Make sure that the safety distance is complied with.
DWARNING!
Risk of death due to explosions or electric shock!
Drilling through gas, water or electrical lines can lead to
hazardous situations.
Ensure that there are no lines in the wall at the fastening
points.
Ø 8
Determine the locations of the fastening points and mark
them.
Drill the holes in the wall.
Insert the wall plugs into the holes.
Screw the chimney fastening bracket on.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BWH 90 ST at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BWH 90 ST in the language / languages: English as an attachment in your email.

The manual is 8.27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BWH 90 ST

Berbel BWH 90 ST User Manual - German - 32 pages

Berbel BWH 90 ST User Manual - Dutch - 32 pages

Berbel BWH 90 ST User Manual - French - 32 pages

Berbel BWH 90 ST User Manual - Italian - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info