784192
21
Zoom out
Zoom in
Previous page
1/24
Next page
21
Maintenance
6006262_0 – 03.06.2022
EN
Unscrew the screws on the top of the filter.
Remove the cover.
Empty the filter completely.
Fill the filter with new charcoal up to the maximum level.
Screw the cover back on to the top of the filter.
Clean the filter from the outside (e.g. through extraction
with a vacuum cleaner).
Take hold of the filter at the handles.
Carefully insert the filter again.
Place the cover on the device.
Screw the cover tight again.
6.2.3 Fault rectification
Possible faults are described below:
Description of the fault.
yPossible cause.
Remedy.
The lighting does not work.
yThe device software requires a restart.
Interrupt the power supply for approx. 10 seconds.
yThe lamp has blown.
Please consult your dealer or customer services.
Fan and lighting do not work.
yNo power supply.
Check that the all-pole mains switch is connected.
Switch the mains switch on.
yThe breaker may have been tripped or is defective.
Check to see if the breaker has tripped.
If you use electric circuit breakers, turn the circuit
breaker on again.
For other types of fuse, consult a qualified electrician.
The fan does not work.
yThe device is not switched on.
Check all power levels.
D“4.2.1 Normal operation (page 16).
yThe device is connected to a window contact switch and
the window is closed.
Open the window.
yThe device is connected to a safety device. The safety
device detects a critical under-pressure.
Open a window.
Wait until the air pressure returns to normal.
Smells occur during operation.
yThe filter filling is used up.
Change the filter filling.
D“6.2.2 Replacing filter filling” (page 20).
Poor device performance.
yThe recirculated air filter is clogged.
Replace the filter filling of the recirculated air filter.
D“6.2.2 Replacing filter filling” (page 20).
The smoke can settle on furniture, the fronts of kitchen units and
the ceiling.
ySmoke development by heating cooking oils and cooking
fats to too high a temperature.
Note the smoke point of the cooking oil or fat you
are using. You can obtain this information from the
respective manufacturer.
Control panel does not react after being touched several times.
yThe control panel is soiled.
Clean the control panel.
D“5. Cleaning” (page 18).
yThe device software requires a restart.
Interrupt the power supply for approx. 10 seconds.
Moisture in the device.
yDripping or splashing water has penetrated the device.
yLiquid (e.g. from vases, bottles on the device) has
penetrated the device.
Immediately shut off the power supply, by removing
the fuse.
Make sure that the power supply cannot be
unintentionally reconnected. For example by tasking
a person with ensuring that the fuse/breaker is not
restored/switched on.
Ensure that no more liquid can penetrate the device.
Allow the device to dry.
Have the device checked and repaired by qualified,
specialist personnel prior to using the device again.
If a fault persists:
Please consult your dealer or customer services.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BKH 80 ST permalyt at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BKH 80 ST permalyt in the language / languages: English as an attachment in your email.

The manual is 4.51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BKH 80 ST permalyt

Berbel BKH 80 ST permalyt User Manual - German - 24 pages

Berbel BKH 80 ST permalyt User Manual - Dutch - 24 pages

Berbel BKH 80 ST permalyt User Manual - French - 24 pages

Berbel BKH 80 ST permalyt User Manual - Italian - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info