Operation
6006211_a – 18.05.2022
EN
4.5 Extraction operation
Button Function
Extraction is selected with the corresponding
button.
Press the button.
yThe button illuminates brightly.
yThe slider and the power button
illuminate.
yFurther entries only apply for extraction.
Choose a power level by tapping or
swiping the slider.
yThe selected power level is displayed.
yThe extraction is started accordingly.
Press the button to start the power stage
(“booster”).
yThe selected power level is displayed.
yThe extraction is started accordingly.
If the BKA DL cover (optional) is used:
Make sure that the cover is removed and the Powermover
is inserted again.
To achieve an optimal efficiency in removing cooking fumes:
Move the Powermover in the direction of the side with
the lowest proportion of cooking fumes.
The Powermover is magnetically held in the centre and at
the sides.
During the cooking process, switch to a power level that
is appropriate for the intensity of the cooking vapours:
yPower level 1 - lowest fan power - when simmering
food.
yPower level 5 - medium fan power - when cooking on
one cooking zone.
yPower level 9 - high fan power - when cooking on
several cooking zones.
If the intensity of the cooking vapours does not subside,
switch to a higher power level.
Switch to the POWER setting if frying. The device switches
back to power level 9 automatically after 6 minutes.
Check the fresh air supply at regular intervals.
Turn on the run-on function when you have finished
cooking.
Turn off the device after use. If the automatic run-on
function is activated, the run-on time (10 minutes) starts
in power level 1.
4.5.1 Operating modes
There are three operating modes available for extraction by
the device. The selected operating mode is shown in the
display in the centre of the control panel.
Display Operating mode
Press the button for extraction for
3 seconds.
The operating mode switches in the
sequence: Semi-automatic -> Automatic ->
Manual -> Semi-automatic, etc.
In delivery condition, semi-automatic mode is
activated.
Semi-automatic mode
With activation of the cooking zone, the fan
is also switched on automatically to power
level 5. In further operation, the connection
between the selection of the cooking zone
level and fan power is severed.
The fan switches off when the cooking zone is
switched off or the automatic run-on starts.
Automatic mode
The setting of the fan power takes
place automatically. The fan is adjusted
automatically to a suitable power level
depending on the cooking zone level that is
selected.
If multiple cooking zones are used, the power
level is adjusted accordingly. The cooking
zone with the highest active power level
determines the fan power.
The power level of the fan can also be
changed manually during operation.
The device remains in automatic mode.
Manual mode
The setting of the fan power takes place
manually. The connection between the
selection of the cooking zone level and fan
power selection is severed.
Automatic mode includes pot recognition. If the cookware is
removed from all cooking zones, the device slowly reduces
fan output to power level 1.
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BKA 83 DLP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BKA 83 DLP in the language / languages: English as an attachment in your email.

The manual is 14.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BKA 83 DLP

Berbel BKA 83 DLP User Manual - German - 44 pages

Berbel BKA 83 DLP User Manual - Dutch - 44 pages

Berbel BKA 83 DLP User Manual - French - 44 pages

Berbel BKA 83 DLP User Manual - Italian - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info